Please login if you have access to particular applications.
Deployment Details
Survey: - IN2024_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 46
Gear: Autosal Salinometer,CTD 25 - SN 1354,Chlorophyll - CTD 25 - Wetlabs ECO,Conductivity CTD 25 - SN 4774,Licor - CTD 25 - SN 70562,Oxygen CTD 25-SBE 43-SN 3155,Pressure CTD 25,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 25 - Wetlabs ECO,Temperature CTD 25-SN 2751,Transmissometer - CTD 25 -CST-1421DR
When: 2024-02-06 07:54 to 2024-02-06 11:22 UTC
Where: 60° 24.0' S 115° 00.2' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 36 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 2.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 4.8 | 340.23 | 33.952 | 27.10 | 2.53 | 1.74 | 0.27 | 0.27 | 16.39 |
| 34 | 13 | < 0.02 | < 0.02 | < 0.02 | 2.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 13 | 340.18 | 33.951 | 27.07 | 2.54 | 1.74 | 0.28 | 0.27 | 16.40 |
| 32 | 35.1 | < 0.02 | < 0.02 | < 0.02 | 2.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 35.1 | 340.63 | 33.951 | 27.10 | 2.42 | 1.74 | 0.27 | 0.26 | 16.88 |
| 29 | 66.9 | 350.99 | 33.934 | 26.87 | 1.22 | 1.79 | 0.41 | 0.25 | 21.84 |
| 30 | 67 | < 0.02 | < 0.02 | < 0.02 | 1.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 90.3 | 346.70 | 33.970 | 27.70 | 1.02 | 1.94 | 0.81 | 0.26 | 29.60 |
| 26 | 135.1 | 328.30 | 34.071 | 30.61 | -0.00 | 2.14 | 0.60 | 0.23 | 43.63 |
| 27 | 135.1 | < 0.02 | < 0.02 | < 0.02 | 0.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 210.2 | 189.94 | 34.467 | 35.63 | 2.03 | 2.43 | < 0.02 | < 0.02 | 70.37 |
| 23 | 325.2 | 176.90 | 34.586 | 35.14 | 2.07 | 2.38 | < 0.02 | < 0.02 | 78.81 |
| 24 | 325.3 | < 0.02 | < 0.02 | < 0.02 | 2.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 550.2 | 182.17 | 34.683 | 33.38 | 2.04 | 2.26 | < 0.02 | < 0.02 | 83.37 |
| 21 | 750.1 | 188.51 | 34.714 | 32.49 | 1.88 | 2.20 | < 0.02 | < 0.02 | 87.11 |
| 20 | 950.1 | 195.44 | 34.734 | 31.74 | 1.76 | 2.16 | < 0.02 | < 0.02 | 90.49 |
| 18 | 1180.3 | 201.56 | 34.742 | 31.40 | 1.61 | 2.15 | < 0.02 | < 0.02 | 94.49 |
| 19 | 1180.4 | < 0.02 | < 0.02 | < 0.02 | 1.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 1410 | 204.46 | 34.736 | 31.63 | 1.40 | 2.17 | < 0.02 | < 0.02 | 100.76 |
| 16 | 1700.3 | 207.67 | 34.725 | 32.03 | 1.15 | 2.20 | < 0.02 | < 0.02 | 107.32 |
| 15 | 1990.2 | 210.62 | 34.714 | 32.43 | 0.95 | 2.23 | < 0.02 | < 0.02 | 113.92 |
| 14 | 2289.8 | 213.52 | 34.703 | 32.82 | 0.74 | 2.26 | < 0.02 | < 0.02 | 119.95 |
| 13 | 2600.5 | 217.32 | 34.692 | 33.11 | 0.55 | 2.27 | < 0.02 | < 0.02 | 125.02 |
| 12 | 2950.2 | 222.10 | 34.683 | 33.19 | 0.39 | 2.29 | < 0.02 | < 0.02 | 129.04 |
| 11 | 3210.1 | 225.49 | 34.678 | 33.25 | 0.29 | 2.29 | < 0.02 | < 0.02 | 131.66 |
| 10 | 3490.1 | 228.84 | 34.674 | 33.28 | 0.21 | 2.29 | < 0.02 | < 0.02 | 134.44 |
| 9 | 3810.3 | 231.66 | 34.669 | 33.17 | 0.13 | 2.28 | < 0.02 | < 0.02 | 133.08 |
| 7 | 4009.7 | 234.07 | 34.665 | 33.14 | 0.08 | 2.26 | < 0.02 | < 0.02 | 133.00 |
| 8 | 4009.7 | < 0.02 | < 0.02 | < 0.02 | 0.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 4310.2 | 238.71 | 34.659 | 33.00 | -0.00 | 2.27 | < 0.02 | < 0.02 | 128.94 |
| 6 | 4310.3 | < 0.02 | < 0.02 | < 0.02 | -0.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 4449.8 | < 0.02 | < 0.02 | < 0.02 | -0.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 4449.8 | 243.63 | 34.653 | 32.80 | -0.10 | 2.26 | < 0.02 | < 0.02 | 122.56 |
| 2 | 4540.9 | < 0.02 | < 0.02 | < 0.02 | -0.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 4540.9 | 244.21 | 34.653 | 32.80 | -0.11 | 2.26 | < 0.02 | < 0.02 | 124.30 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
| Chlorophyll - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 25 - SN 4774 | Seabird | SBE4C | 4774 | |
| Licor - CTD 25 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 25-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Turbidity (%) |
| Temperature CTD 25-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 25 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |