Please login if you have access to particular applications.
Deployment Details
Survey: - IN2024_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 44
Gear: Autosal Salinometer,CTD 25 - SN 1354,Chlorophyll - CTD 25 - Wetlabs ECO,Conductivity CTD 25 - SN 4774,Licor - CTD 25 - SN 70562,Oxygen CTD 25-SBE 43-SN 3155,Pressure CTD 25,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 25 - Wetlabs ECO,Temperature CTD 25-SN 2751,Transmissometer - CTD 25 -CST-1421DR
When: 2024-02-05 16:13 to 2024-02-05 19:38 UTC
Where: 61° 30.6' S 115° 00.7' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 35 | 5.7 | 347.73 | 33.885 | 25.64 | 1.83 | 1.59 | 0.10 | 0.27 | 22.77 |
| 36 | 5.7 | < 0.02 | < 0.02 | < 0.02 | 1.83 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 15.3 | < 0.02 | < 0.02 | < 0.02 | 1.83 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 15.3 | 347.69 | 33.885 | 25.66 | 1.83 | 1.59 | 0.10 | 0.27 | 22.78 |
| 31 | 40.2 | 349.03 | 33.890 | 25.79 | 1.69 | 1.65 | 0.19 | 0.27 | 23.17 |
| 32 | 40.3 | < 0.02 | < 0.02 | < 0.02 | 1.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 50.4 | < 0.02 | < 0.02 | < 0.02 | 1.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 50.4 | 349.87 | 33.934 | 26.77 | 1.03 | 1.80 | 0.55 | 0.25 | 26.81 |
| 27 | 95.5 | 327.68 | 34.075 | 30.34 | -0.25 | 2.14 | 0.68 | 0.19 | 46.34 |
| 28 | 95.6 | < 0.02 | < 0.02 | < 0.02 | -0.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 160.4 | 203.70 | 34.436 | 35.13 | 1.59 | 2.40 | < 0.02 | 0.02 | 69.72 |
| 26 | 160.4 | < 0.02 | < 0.02 | < 0.02 | 1.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 200.8 | 185.88 | 34.517 | 35.30 | 1.91 | 2.42 | < 0.02 | < 0.02 | 74.98 |
| 22 | 340.6 | 176.77 | 34.639 | 34.29 | 2.05 | 2.35 | < 0.02 | 0.03 | 81.60 |
| 23 | 340.6 | < 0.02 | < 0.02 | < 0.02 | 2.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 520.6 | 184.27 | 34.695 | 32.78 | 2.01 | 2.25 | < 0.02 | < 0.02 | 83.85 |
| 20 | 780.3 | 194.10 | 34.738 | 31.65 | 1.83 | 2.18 | < 0.02 | < 0.02 | 88.19 |
| 18 | 1065.6 | 200.97 | 34.738 | 31.34 | 1.58 | 2.16 | < 0.02 | < 0.02 | 94.33 |
| 19 | 1065.8 | < 0.02 | < 0.02 | < 0.02 | 1.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 1331.2 | 205.17 | 34.733 | 31.52 | 1.36 | 2.18 | < 0.02 | < 0.02 | 100.73 |
| 16 | 1681.6 | 208.52 | 34.721 | 31.98 | 1.08 | 2.19 | < 0.02 | < 0.02 | 108.43 |
| 15 | 2001.1 | 211.20 | 34.707 | 32.40 | 0.83 | 2.22 | < 0.02 | < 0.02 | 115.76 |
| 14 | 2300 | 214.86 | 34.697 | 32.71 | 0.64 | 2.26 | < 0.02 | < 0.02 | 121.71 |
| 13 | 2600 | 219.24 | 34.689 | 32.86 | 0.47 | 2.28 | < 0.02 | < 0.02 | 126.00 |
| 11 | 2901.5 | 223.04 | 34.682 | 32.86 | 0.34 | 2.28 | < 0.02 | < 0.02 | 129.24 |
| 12 | 2901.6 | < 0.02 | < 0.02 | < 0.02 | 0.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 3301.2 | < 0.02 | < 0.02 | < 0.02 | 0.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 3301.2 | 227.82 | 34.675 | 32.94 | 0.21 | 2.29 | < 0.02 | < 0.02 | 132.36 |
| 7 | 3700.4 | 231.66 | 34.669 | 32.98 | 0.11 | 2.29 | < 0.02 | < 0.02 | 134.01 |
| 8 | 3700.5 | < 0.02 | < 0.02 | < 0.02 | 0.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 4000.7 | 235.50 | 34.664 | 32.88 | 0.04 | 2.28 | < 0.02 | < 0.02 | 133.11 |
| 5 | 4200.7 | 238.00 | 34.660 | 32.86 | -0.01 | 2.27 | < 0.02 | < 0.02 | 131.20 |
| 3 | 4380.8 | 245.23 | 34.651 | 32.62 | -0.14 | 2.26 | < 0.02 | < 0.02 | 120.66 |
| 4 | 4380.9 | < 0.02 | < 0.02 | < 0.02 | -0.14 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 4411.9 | 245.05 | 34.652 | 32.61 | -0.14 | 2.25 | < 0.02 | < 0.02 | 120.62 |
| 2 | 4412 | < 0.02 | < 0.02 | < 0.02 | -0.14 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
| Chlorophyll - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 25 - SN 4774 | Seabird | SBE4C | 4774 | |
| Licor - CTD 25 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 25-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Turbidity (%) |
| Temperature CTD 25-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 25 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |