Please login if you have access to particular applications.
Deployment Details
Survey: - IN2024_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 42
Gear: Autosal Salinometer,CTD 25 - SN 1354,Chlorophyll - CTD 25 - Wetlabs ECO,Conductivity CTD 25 - SN 4774,Licor - CTD 25 - SN 70562,Oxygen CTD 25-SBE 43-SN 3155,Pressure CTD 25,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 25 - Wetlabs ECO,Temperature CTD 25-SN 2751,Transmissometer - CTD 25 -CST-1421DR
When: 2024-02-05 04:15 to 2024-02-05 04:47 UTC
Where: 61° 58.0' S 113° 35.4' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 33 | 4.7 | < 0.02 | < 0.02 | < 0.02 | 1.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 1.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 1.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 5.1 | 350.81 | 33.802 | 25.20 | 1.94 | 1.55 | 0.07 | 0.27 | 29.57 |
| 36 | 5.1 | < 0.02 | < 0.02 | < 0.02 | 1.93 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 5.3 | < 0.02 | < 0.02 | < 0.02 | 1.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 10.2 | < 0.02 | < 0.02 | < 0.02 | 1.93 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 10.2 | 350.81 | 33.802 | 25.14 | 1.93 | 1.56 | 0.05 | 0.27 | 29.41 |
| 27 | 34.2 | < 0.02 | < 0.02 | < 0.02 | 1.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 34.2 | 352.24 | 33.805 | 25.23 | 1.83 | 1.57 | 0.07 | 0.26 | 29.22 |
| 28 | 34.2 | < 0.02 | < 0.02 | < 0.02 | 1.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 34.5 | < 0.02 | < 0.02 | < 0.02 | 1.83 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 40.9 | < 0.02 | < 0.02 | < 0.02 | 0.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 40.9 | < 0.02 | < 0.02 | < 0.02 | 0.83 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 40.9 | < 0.02 | < 0.02 | < 0.02 | 0.86 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 41 | < 0.02 | < 0.02 | < 0.02 | 0.92 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 41 | 352.42 | 33.882 | < 0.02 | 0.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 41.1 | < 0.02 | < 0.02 | < 0.02 | 0.86 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 90.2 | < 0.02 | < 0.02 | < 0.02 | -0.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 90.2 | < 0.02 | < 0.02 | < 0.02 | -0.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 90.2 | 307.18 | 34.118 | 30.74 | -0.07 | 2.18 | 0.79 | 0.19 | 54.29 |
| 14 | 90.2 | < 0.02 | < 0.02 | < 0.02 | -0.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 90.2 | < 0.02 | < 0.02 | < 0.02 | -0.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 90.3 | < 0.02 | < 0.02 | < 0.02 | -0.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 210.7 | 195.79 | 34.525 | 34.87 | 1.56 | 2.37 | < 0.02 | 0.03 | 77.20 |
| 9 | 210.8 | < 0.02 | < 0.02 | < 0.02 | 1.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 210.8 | < 0.02 | < 0.02 | < 0.02 | 1.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 210.8 | < 0.02 | < 0.02 | < 0.02 | 1.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 210.8 | < 0.02 | < 0.02 | < 0.02 | 1.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 210.8 | < 0.02 | < 0.02 | < 0.02 | 1.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 400.7 | 184.63 | 34.675 | 33.52 | 1.88 | 2.29 | < 0.02 | 0.02 | 85.06 |
| 1 | 400.7 | < 0.02 | < 0.02 | < 0.02 | 1.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 400.9 | < 0.02 | < 0.02 | < 0.02 | 1.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 400.9 | < 0.02 | < 0.02 | < 0.02 | 1.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 400.9 | < 0.02 | < 0.02 | < 0.02 | 1.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 401 | < 0.02 | < 0.02 | < 0.02 | 1.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
| Chlorophyll - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 25 - SN 4774 | Seabird | SBE4C | 4774 | |
| Licor - CTD 25 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 25-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Turbidity (%) |
| Temperature CTD 25-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 25 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |