Please login if you have access to particular applications.
Deployment Details
Survey: - IN2024_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 38
Gear: Autosal Salinometer,CTD 25 - SN 1354,Chlorophyll - CTD 25 - Wetlabs ECO,Conductivity CTD 25 - SN 4774,Licor - CTD 25 - SN 70562,Oxygen CTD 25-SBE 43-SN 3155,Pressure CTD 25,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 25 - Wetlabs ECO,Temperature CTD 25-SN 2751,Transmissometer - CTD 25 -CST-1421DR
When: 2024-02-03 05:04 to 2024-02-03 07:57 UTC
Where: 62° 47.1' S 113° 18.0' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 35 | 4.1 | 348.94 | 33.828 | 26.48 | 1.35 | 1.74 | 0.20 | 0.23 | 47.14 |
| 36 | 4.2 | < 0.02 | < 0.02 | < 0.02 | 1.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 15 | < 0.02 | < 0.02 | < 0.02 | 1.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 15 | 349.47 | 33.832 | 26.45 | 1.16 | 1.74 | 0.20 | 0.23 | 47.07 |
| 32 | 35 | < 0.02 | < 0.02 | < 0.02 | 0.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 35 | 352.55 | 33.911 | 26.68 | 0.95 | 1.76 | 0.19 | 0.19 | 46.53 |
| 29 | 55.3 | 335.45 | 34.019 | 28.07 | 0.05 | 1.89 | 0.37 | 0.17 | 53.73 |
| 30 | 55.3 | < 0.02 | < 0.02 | < 0.02 | 0.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 79.7 | 287.62 | 34.232 | 30.52 | -0.23 | 2.13 | 0.58 | 0.17 | 67.76 |
| 28 | 79.8 | < 0.02 | < 0.02 | < 0.02 | -0.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 99.9 | 260.82 | 34.357 | 31.64 | 0.00 | 2.19 | 0.38 | 0.19 | 74.88 |
| 25 | 150.3 | 204.95 | 34.600 | 32.86 | 1.12 | 2.26 | < 0.02 | 0.03 | 85.46 |
| 24 | 200.3 | 195.66 | 34.664 | 32.59 | 1.42 | 2.25 | < 0.02 | < 0.02 | 88.29 |
| 22 | 270.3 | 194.14 | 34.700 | 32.17 | 1.52 | 2.24 | < 0.02 | < 0.02 | 90.93 |
| 23 | 270.4 | < 0.02 | < 0.02 | < 0.02 | 1.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 380.4 | 196.02 | 34.720 | 31.72 | 1.53 | 2.21 | < 0.02 | < 0.02 | 93.26 |
| 20 | 520.6 | 198.92 | < 0.02 | 31.58 | 1.45 | 2.20 | < 0.02 | < 0.02 | 96.55 |
| 18 | 660.8 | 201.78 | 34.730 | 31.52 | 1.36 | 2.19 | < 0.02 | < 0.02 | 99.58 |
| 19 | 661.1 | < 0.02 | < 0.02 | < 0.02 | 1.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 901 | 205.89 | < 0.02 | 31.63 | 1.17 | 2.21 | < 0.02 | < 0.02 | 105.46 |
| 16 | 1151 | 208.39 | 34.718 | < 0.02 | 1.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 1400.6 | 211.60 | 34.708 | 32.19 | 0.81 | 2.25 | < 0.02 | < 0.02 | 115.89 |
| 14 | 1650.7 | 215.49 | < 0.02 | 32.45 | 0.62 | 2.27 | < 0.02 | < 0.02 | 120.04 |
| 13 | 1900.7 | 218.97 | 34.688 | 32.57 | 0.46 | 2.28 | < 0.02 | < 0.02 | 123.37 |
| 12 | 2300.5 | 224.20 | 34.680 | 32.74 | 0.27 | 2.30 | < 0.02 | < 0.02 | 128.47 |
| 10 | 2700 | 228.93 | 34.673 | 32.72 | 0.13 | 2.29 | < 0.02 | < 0.02 | 131.34 |
| 11 | 2700.3 | < 0.02 | < 0.02 | < 0.02 | 0.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 3000.9 | 233.04 | 34.668 | 32.68 | 0.04 | 2.29 | < 0.02 | < 0.02 | 130.53 |
| 8 | 3300.9 | 236.12 | 34.663 | 32.69 | -0.03 | 2.29 | < 0.02 | < 0.02 | 132.85 |
| 7 | 3500.6 | 239.52 | 34.659 | 32.52 | -0.09 | 2.27 | < 0.02 | < 0.02 | 128.42 |
| 5 | 3750.2 | 245.10 | 34.652 | 32.32 | -0.19 | 2.27 | < 0.02 | < 0.02 | 120.67 |
| 6 | 3750.4 | < 0.02 | < 0.02 | < 0.02 | -0.19 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 3850.3 | 246.62 | 34.649 | 32.24 | -0.24 | 2.26 | < 0.02 | < 0.02 | 117.20 |
| 4 | 3850.4 | < 0.02 | < 0.02 | < 0.02 | -0.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 3892.2 | 246.35 | 34.648 | 32.26 | -0.23 | 2.27 | < 0.02 | < 0.02 | 117.35 |
| 2 | 3892.3 | < 0.02 | < 0.02 | < 0.02 | -0.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
| Chlorophyll - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 25 - SN 4774 | Seabird | SBE4C | 4774 | |
| Licor - CTD 25 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 25-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Turbidity (%) |
| Temperature CTD 25-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 25 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |