Please login if you have access to particular applications.
Deployment Details
Survey: - IN2024_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 37
Gear: Autosal Salinometer,CTD 25 - SN 1354,Chlorophyll - CTD 25 - Wetlabs ECO,Conductivity CTD 25 - SN 4774,Licor - CTD 25 - SN 70562,Oxygen CTD 25-SBE 43-SN 3155,Pressure CTD 25,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 25 - Wetlabs ECO,Temperature CTD 25-SN 2751,Transmissometer - CTD 25 -CST-1421DR
When: 2024-02-02 19:46 to 2024-02-02 22:40 UTC
Where: 63° 16.8' S 113° 20.0' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 35 | 5.5 | 347.55 | 33.790 | 26.58 | 1.08 | 1.78 | 0.46 | 0.23 | 52.73 |
| 36 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 1.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 20.4 | 347.73 | 33.800 | 26.51 | 1.08 | 1.77 | 0.45 | 0.23 | 52.89 |
| 34 | 20.4 | < 0.02 | < 0.02 | < 0.02 | 1.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 40.4 | 350.50 | 33.986 | 27.01 | -0.09 | 1.80 | 0.11 | 0.16 | 53.57 |
| 32 | 40.5 | < 0.02 | < 0.02 | < 0.02 | -0.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 45.3 | 346.75 | 34.009 | 27.04 | -0.17 | 1.82 | 0.13 | 0.15 | 54.21 |
| 30 | 45.3 | < 0.02 | < 0.02 | < 0.02 | -0.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 60.3 | 297.40 | 34.250 | 30.09 | -0.69 | 2.09 | 0.19 | 0.15 | 68.28 |
| 27 | 80.1 | 263.46 | 34.399 | 31.59 | -0.29 | 2.19 | 0.05 | 0.21 | 76.44 |
| 26 | 115.1 | 221.61 | 34.558 | 32.38 | 0.59 | 2.23 | < 0.02 | 0.06 | 83.64 |
| 25 | 170.4 | 198.12 | 34.668 | 32.39 | 1.35 | 2.24 | < 0.02 | < 0.02 | 88.41 |
| 23 | 230.5 | 196.51 | 34.699 | 32.09 | 1.46 | 2.23 | < 0.02 | < 0.02 | 91.03 |
| 24 | 230.6 | < 0.02 | < 0.02 | < 0.02 | 1.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 280.5 | 197.04 | 34.708 | 32.03 | 1.43 | 2.23 | < 0.02 | < 0.02 | 93.20 |
| 22 | 280.5 | < 0.02 | < 0.02 | < 0.02 | 1.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 410.5 | 199.01 | 34.726 | 31.78 | 1.42 | 2.21 | < 0.02 | < 0.02 | 96.67 |
| 19 | 530.5 | < 0.02 | < 0.02 | < 0.02 | 1.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 530.5 | 202.67 | 34.728 | 31.68 | 1.34 | 2.20 | < 0.02 | < 0.02 | 99.94 |
| 17 | 650.4 | 204.37 | 34.728 | 31.74 | 1.25 | 2.21 | < 0.02 | < 0.02 | 103.02 |
| 16 | 850.5 | 206.65 | 34.721 | 31.93 | 1.08 | 2.22 | < 0.02 | < 0.02 | 107.70 |
| 15 | 1050.3 | 209.55 | 34.714 | 32.13 | 0.92 | 2.24 | < 0.02 | < 0.02 | 112.64 |
| 13 | 1350.8 | 212.99 | 34.703 | 32.52 | 0.71 | 2.27 | < 0.02 | < 0.02 | 118.79 |
| 14 | 1351 | < 0.02 | < 0.02 | < 0.02 | 0.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 1750.7 | 218.79 | 34.689 | 32.86 | 0.44 | 2.29 | < 0.02 | < 0.02 | 125.32 |
| 11 | 2200.7 | 227.59 | 34.673 | 32.84 | 0.18 | 2.29 | < 0.02 | < 0.02 | 126.22 |
| 10 | 2400.8 | 230.27 | 34.670 | 32.85 | 0.10 | 2.29 | < 0.02 | < 0.02 | 127.11 |
| 9 | 2699.9 | 235.10 | 34.663 | 32.81 | -0.02 | 2.28 | < 0.02 | < 0.02 | 125.15 |
| 8 | 3200.6 | < 0.02 | < 0.02 | < 0.02 | -0.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 3200.6 | 241.97 | 34.655 | 32.59 | -0.16 | 2.27 | < 0.02 | < 0.02 | 119.29 |
| 6 | 3460.2 | < 0.02 | < 0.02 | < 0.02 | -0.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 3460.2 | 245.77 | 34.651 | 32.52 | -0.23 | 2.27 | < 0.02 | < 0.02 | 115.80 |
| 4 | 3510.4 | < 0.02 | < 0.02 | < 0.02 | -0.27 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 3510.4 | 246.89 | 34.649 | 32.45 | -0.27 | 2.26 | < 0.02 | < 0.02 | 116.00 |
| 2 | 3561 | < 0.02 | < 0.02 | < 0.02 | -0.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 3561 | 247.38 | 34.649 | 32.41 | -0.26 | 2.26 | < 0.02 | 0.02 | 116.11 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
| Chlorophyll - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 25 - SN 4774 | Seabird | SBE4C | 4774 | |
| Licor - CTD 25 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 25-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Turbidity (%) |
| Temperature CTD 25-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 25 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |