Please login if you have access to particular applications.
Deployment Details
Survey: - IN2024_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 36
Gear: Autosal Salinometer,CTD 25 - SN 1354,Chlorophyll - CTD 25 - Wetlabs ECO,Conductivity CTD 25 - SN 4774,Licor - CTD 25 - SN 70562,Oxygen CTD 25-SBE 43-SN 3155,Pressure CTD 25,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 25 - Wetlabs ECO,Temperature CTD 25-SN 2751,Transmissometer - CTD 25 -CST-1421DR
When: 2024-02-02 06:36 to 2024-02-02 09:16 UTC
Where: 63° 38.4' S 113° 19.5' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 35 | 4.6 | 353.63 | 33.518 | 24.04 | 1.11 | 1.55 | 0.22 | 0.23 | 51.58 |
| 36 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 1.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 20.1 | 356.84 | 33.565 | 24.04 | 0.91 | 1.55 | 0.14 | 0.22 | 51.54 |
| 34 | 20.1 | < 0.02 | < 0.02 | < 0.02 | 0.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 35.2 | < 0.02 | < 0.02 | < 0.02 | -0.14 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 35.2 | 343.00 | 33.962 | 26.40 | -0.15 | 1.76 | 0.04 | 0.16 | 58.37 |
| 29 | 50 | 295.61 | 34.228 | 29.42 | -0.41 | 2.05 | 0.25 | 0.16 | 71.05 |
| 30 | 50.1 | < 0.02 | < 0.02 | < 0.02 | -0.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 124.8 | 201.38 | 34.664 | 32.26 | 1.17 | 2.24 | < 0.02 | 0.04 | 90.87 |
| 26 | 160.1 | 195.84 | 34.707 | 32.14 | 1.41 | 2.23 | < 0.02 | 0.02 | 93.46 |
| 27 | 160.1 | < 0.02 | < 0.02 | < 0.02 | 1.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 224.9 | 195.79 | 34.718 | 32.04 | 1.43 | 2.22 | < 0.02 | 0.02 | 95.46 |
| 24 | 400.2 | < 0.02 | < 0.02 | < 0.02 | 1.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 400.2 | 200.71 | 34.727 | 31.74 | 1.32 | 2.21 | < 0.02 | < 0.02 | 100.50 |
| 21 | 600.1 | 204.99 | 34.723 | 31.76 | 1.16 | 2.21 | < 0.02 | < 0.02 | 104.86 |
| 22 | 600.1 | < 0.02 | < 0.02 | < 0.02 | 1.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 900.5 | 211.29 | 34.707 | 32.00 | 0.83 | 2.24 | < 0.02 | < 0.02 | 112.37 |
| 18 | 1199.9 | 215.98 | 34.696 | 32.28 | 0.59 | 2.25 | < 0.02 | < 0.02 | 118.51 |
| 19 | 1200 | < 0.02 | < 0.02 | < 0.02 | 0.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 1501.1 | 220.94 | 34.685 | 32.46 | 0.36 | 2.26 | < 0.02 | < 0.02 | 124.34 |
| 17 | 1501.2 | < 0.02 | < 0.02 | < 0.02 | 0.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 1798.4 | 225.49 | 34.678 | 32.65 | 0.20 | 2.26 | < 0.02 | < 0.02 | 128.24 |
| 15 | 1798.4 | < 0.02 | < 0.02 | < 0.02 | 0.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 2050.6 | 230.14 | 34.670 | 32.67 | 0.07 | 2.26 | < 0.02 | < 0.02 | 127.20 |
| 13 | 2050.7 | < 0.02 | < 0.02 | < 0.02 | 0.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 2300.2 | 234.20 | 34.664 | 32.54 | -0.03 | 2.27 | < 0.02 | < 0.02 | 125.64 |
| 10 | 2600.6 | 239.83 | 34.657 | 32.32 | -0.15 | 2.26 | < 0.02 | < 0.02 | 121.11 |
| 8 | 2800.6 | 243.36 | 34.652 | 32.27 | -0.23 | 2.25 | < 0.02 | < 0.02 | 114.87 |
| 9 | 2800.9 | < 0.02 | < 0.02 | < 0.02 | -0.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 3000.2 | 244.70 | 34.651 | 32.18 | -0.25 | 2.25 | < 0.02 | < 0.02 | 113.57 |
| 7 | 3000.4 | < 0.02 | < 0.02 | < 0.02 | -0.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 3220.2 | 248.67 | 34.646 | 32.14 | -0.32 | 2.24 | < 0.02 | < 0.02 | 111.61 |
| 3 | 3270.6 | 250.46 | 34.641 | 32.11 | -0.36 | 2.24 | < 0.02 | < 0.02 | 110.40 |
| 4 | 3270.8 | < 0.02 | < 0.02 | < 0.02 | -0.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 3319.5 | 250.46 | 34.641 | 32.16 | -0.35 | 2.24 | < 0.02 | 0.02 | 110.47 |
| 2 | 3319.6 | < 0.02 | < 0.02 | < 0.02 | -0.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
| Chlorophyll - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 25 - SN 4774 | Seabird | SBE4C | 4774 | |
| Licor - CTD 25 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 25-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Turbidity (%) |
| Temperature CTD 25-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 25 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |