Please login if you have access to particular applications.
Deployment Details
Survey: - IN2024_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 28
Gear: Autosal Salinometer,CTD 25 - SN 1354,Chlorophyll - CTD 25 - Wetlabs ECO,Conductivity CTD 25 - SN 4774,Licor - CTD 25 - SN 70562,Oxygen CTD 25-SBE 43-SN 3155,Pressure CTD 25,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 25 - Wetlabs ECO,Temperature CTD 25-SN 2751,Transmissometer - CTD 25 -CST-1421DR
When: 2024-01-26 21:52 to 2024-01-26 23:48 UTC
Where: 64° 31.3' S 132° 03.1' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 36 | 8.1 | < 0.02 | < 0.02 | < 0.02 | 0.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 8.2 | 352.42 | 33.684 | 22.23 | 0.44 | 1.52 | 1.25 | 0.13 | 37.93 |
| 34 | 15.6 | < 0.02 | < 0.02 | < 0.02 | 0.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 15.7 | 352.46 | 33.686 | 22.24 | 0.43 | 1.53 | 1.25 | 0.13 | 37.98 |
| 32 | 21.4 | < 0.02 | < 0.02 | < 0.02 | 0.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 21.4 | 351.79 | 33.726 | 22.80 | 0.40 | 1.57 | 1.21 | 0.13 | 39.33 |
| 29 | 35.2 | 333.57 | 34.181 | 29.41 | -1.56 | 2.10 | 0.63 | 0.14 | 54.54 |
| 30 | 35.3 | < 0.02 | < 0.02 | < 0.02 | -1.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 55.2 | 327.10 | 34.259 | 30.15 | -1.71 | 2.11 | 0.43 | 0.14 | 57.43 |
| 28 | 55.2 | < 0.02 | < 0.02 | < 0.02 | -1.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 85.6 | < 0.02 | < 0.02 | < 0.02 | -1.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 85.6 | 320.62 | 34.307 | 30.88 | -1.74 | 2.13 | 0.15 | 0.15 | 60.57 |
| 23 | 105.5 | 318.88 | 34.327 | 31.12 | -1.74 | 2.13 | 0.06 | 0.12 | 61.89 |
| 24 | 105.6 | < 0.02 | < 0.02 | < 0.02 | -1.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 145.3 | < 0.02 | < 0.02 | < 0.02 | -1.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 145.4 | < 0.02 | < 0.02 | < 0.02 | -1.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 145.4 | 315.49 | 34.370 | 31.12 | -1.69 | 2.13 | < 0.02 | 0.05 | 65.44 |
| 18 | 294.8 | 280.74 | 34.488 | 31.65 | -0.87 | 2.16 | < 0.02 | 0.03 | 76.16 |
| 19 | 294.9 | < 0.02 | < 0.02 | < 0.02 | -0.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 405.3 | 287.75 | 34.514 | 31.60 | -1.14 | 2.16 | < 0.02 | 0.02 | 80.76 |
| 16 | 510.5 | < 0.02 | < 0.02 | < 0.02 | -0.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 510.5 | 275.69 | 34.558 | 31.91 | -0.91 | 2.19 | < 0.02 | 0.02 | 87.93 |
| 14 | 655.3 | 254.70 | 34.609 | 32.29 | -0.46 | 2.22 | < 0.02 | 0.02 | 100.01 |
| 12 | 785.4 | 241.79 | 34.642 | 32.66 | -0.17 | 2.25 | < 0.02 | 0.02 | 109.99 |
| 13 | 785.4 | < 0.02 | < 0.02 | < 0.02 | -0.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 885.5 | 251.08 | 34.629 | 32.58 | -0.43 | 2.24 | < 0.02 | 0.02 | 105.81 |
| 10 | 1050.4 | < 0.02 | < 0.02 | < 0.02 | -0.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 1050.5 | 247.51 | 34.642 | 32.63 | -0.38 | 2.23 | < 0.02 | 0.02 | 108.38 |
| 7 | 1225.2 | 249.88 | 34.641 | 32.59 | -0.44 | 2.24 | < 0.02 | 0.02 | 107.27 |
| 8 | 1225.2 | < 0.02 | < 0.02 | < 0.02 | -0.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 1376.7 | 248.23 | 34.647 | 32.67 | -0.41 | 2.24 | < 0.02 | < 0.02 | 108.57 |
| 5 | 1450.2 | 248.36 | 34.647 | 32.61 | -0.42 | 2.24 | < 0.02 | 0.02 | 108.37 |
| 4 | 1500.2 | < 0.02 | < 0.02 | < 0.02 | -0.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 1500.3 | 251.49 | 34.642 | 32.62 | -0.46 | 2.24 | < 0.02 | 0.02 | 106.96 |
| 1 | 1518.7 | 252.56 | 34.638 | 32.53 | -0.52 | 2.24 | < 0.02 | 0.02 | 105.92 |
| 2 | 1518.8 | < 0.02 | < 0.02 | < 0.02 | -0.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
| Chlorophyll - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 25 - SN 4774 | Seabird | SBE4C | 4774 | |
| Licor - CTD 25 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 25-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Turbidity (%) |
| Temperature CTD 25-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 25 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |