Deployment Details
Survey: - IN2024_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 27
Gear: Autosal Salinometer,CTD 25 - SN 1354,Chlorophyll - CTD 25 - Wetlabs ECO,Conductivity CTD 25 - SN 4774,Licor - CTD 25 - SN 70562,Oxygen CTD 25-SBE 43-SN 3155,Pressure CTD 25,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 25 - Wetlabs ECO,Temperature CTD 25-SN 2751,Transmissometer - CTD 25 -CST-1421DR
When: 2024-01-25 21:49 to 2024-01-26 00:27 UTC
Where: 64° 00.1' S 131° 59.9' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 35 | 5.9 | 372.61 | 33.617 | 18.58 | 1.42 | 0.99 | 0.03 | 0.20 | 21.90 |
| 36 | 6 | < 0.02 | < 0.02 | < 0.02 | 1.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 15.2 | < 0.02 | < 0.02 | < 0.02 | 1.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 15.2 | 372.79 | 33.647 | 18.65 | 1.37 | 1.00 | 0.05 | 0.19 | 22.19 |
| 32 | 30.3 | < 0.02 | < 0.02 | < 0.02 | 0.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 30.3 | 356.17 | 33.781 | 20.75 | 0.93 | 1.42 | 0.94 | 0.19 | 27.62 |
| 30 | 50.1 | < 0.02 | < 0.02 | < 0.02 | -0.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 50.1 | 322.68 | 34.151 | 29.40 | -0.95 | 2.17 | 1.40 | 0.16 | 54.93 |
| 28 | 65.5 | < 0.02 | < 0.02 | < 0.02 | -1.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 65.5 | 307.80 | 34.239 | 30.70 | -1.12 | 2.18 | 0.78 | 0.15 | 60.30 |
| 26 | 90.2 | < 0.02 | < 0.02 | < 0.02 | -0.99 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 90.2 | 294.14 | 34.326 | 31.63 | -0.99 | 2.18 | 0.13 | 0.13 | 64.34 |
| 24 | 135.5 | < 0.02 | < 0.02 | < 0.02 | -0.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 135.5 | 274.26 | 34.426 | 31.86 | -0.70 | 2.19 | < 0.02 | 0.02 | 70.78 |
| 21 | 190.1 | 230.85 | 34.559 | 32.46 | 0.47 | 2.24 | < 0.02 | < 0.02 | 80.65 |
| 22 | 190.2 | < 0.02 | < 0.02 | < 0.02 | 0.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 290.2 | 222.55 | 34.629 | 32.13 | 0.72 | 2.21 | < 0.02 | < 0.02 | 86.61 |
| 19 | 410.3 | 215.22 | 34.672 | 32.03 | 0.95 | 2.19 | < 0.02 | < 0.02 | 91.75 |
| 17 | 560.4 | 209.19 | 34.707 | 31.93 | 1.11 | 2.19 | < 0.02 | < 0.02 | 98.39 |
| 18 | 560.5 | < 0.02 | < 0.02 | < 0.02 | 1.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 609.9 | 210.40 | 34.705 | 32.00 | 1.07 | 2.20 | < 0.02 | < 0.02 | 99.23 |
| 16 | 610 | < 0.02 | < 0.02 | < 0.02 | 1.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 850.4 | 213.17 | 34.699 | 32.16 | 0.85 | 2.21 | < 0.02 | < 0.02 | 105.68 |
| 13 | 1061.3 | 211.56 | 34.707 | 32.35 | 0.82 | 2.23 | < 0.02 | < 0.02 | 113.28 |
| 12 | 1350.1 | 214.37 | 34.699 | 32.72 | 0.62 | 2.26 | < 0.02 | < 0.02 | 120.31 |
| 11 | 1750.2 | 222.68 | 34.679 | 32.82 | 0.30 | 2.27 | < 0.02 | < 0.02 | 122.76 |
| 10 | 2250.7 | 232.24 | 34.667 | 32.73 | 0.03 | 2.27 | < 0.02 | < 0.02 | 124.01 |
| 9 | 2650.5 | 241.44 | 34.656 | 32.51 | -0.17 | 2.26 | < 0.02 | < 0.02 | 115.72 |
| 8 | 2850.6 | < 0.02 | 34.650 | 32.44 | -0.29 | 2.25 | < 0.02 | < 0.02 | 111.04 |
| 7 | 3000.2 | 248.72 | 34.647 | 32.34 | -0.32 | 2.25 | < 0.02 | < 0.02 | 108.60 |
| 5 | 3140.5 | 250.28 | 34.645 | 32.33 | -0.35 | 2.25 | < 0.02 | < 0.02 | 107.49 |
| 6 | 3140.6 | < 0.02 | < 0.02 | < 0.02 | -0.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 3210.3 | 250.99 | 34.644 | 32.30 | -0.37 | 2.24 | < 0.02 | < 0.02 | 106.98 |
| 4 | 3210.4 | < 0.02 | < 0.02 | < 0.02 | -0.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 3261.9 | < 0.02 | < 0.02 | < 0.02 | -0.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 3262 | 251.04 | 34.644 | 32.35 | -0.36 | 2.24 | < 0.02 | < 0.02 | 106.75 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
| Chlorophyll - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 25 - SN 4774 | Seabird | SBE4C | 4774 | |
| Licor - CTD 25 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 25-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Turbidity (%) |
| Temperature CTD 25-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 25 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |