Please login if you have access to particular applications.
Deployment Details
Survey: - IN2024_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 25
Gear: Autosal Salinometer,CTD 25 - SN 1354,Chlorophyll - CTD 25 - Wetlabs ECO,Conductivity CTD 25 - SN 4774,Licor - CTD 25 - SN 70562,Oxygen CTD 25-SBE 43-SN 3155,Pressure CTD 25,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 25 - Wetlabs ECO,Temperature CTD 25-SN 2751,Transmissometer - CTD 25 -CST-1421DR
When: 2024-01-25 03:21 to 2024-01-25 06:28 UTC
Where: 63° 00.1' S 132° 00.1' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 35 | 4.6 | 353.36 | 33.941 | 26.87 | 1.13 | 1.69 | 0.09 | 0.27 | 26.52 |
| 36 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 1.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 10.1 | 354.12 | 33.949 | 26.83 | 1.08 | 1.70 | 0.10 | 0.27 | 26.78 |
| 33 | 20.1 | < 0.02 | < 0.02 | < 0.02 | 0.98 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 20.1 | 355.32 | 33.967 | 26.87 | 0.98 | 1.74 | 0.11 | 0.26 | 28.03 |
| 31 | 55.1 | < 0.02 | < 0.02 | < 0.02 | 0.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 55.1 | 351.53 | 33.981 | 27.38 | 0.62 | 1.87 | 0.55 | 0.24 | 34.51 |
| 29 | 84.8 | < 0.02 | < 0.02 | < 0.02 | 0.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 84.8 | 332.28 | 34.047 | 29.22 | 0.09 | 2.08 | 0.91 | 0.20 | 43.31 |
| 26 | 100.1 | 286.77 | 34.158 | 32.32 | 0.12 | 2.29 | 0.48 | 0.16 | 51.01 |
| 27 | 100.1 | < 0.02 | < 0.02 | < 0.02 | 0.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 150 | < 0.02 | < 0.02 | < 0.02 | 1.92 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 150 | 187.00 | 34.474 | 35.89 | 1.95 | 2.47 | < 0.02 | 0.03 | 71.81 |
| 23 | 210.2 | 177.97 | 34.547 | 35.62 | 2.02 | 2.45 | < 0.02 | 0.02 | 76.97 |
| 21 | 290.1 | 175.12 | 34.611 | 34.84 | 2.11 | 2.40 | < 0.02 | 0.02 | 80.34 |
| 22 | 290.1 | < 0.02 | < 0.02 | < 0.02 | 2.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 390.1 | 178.02 | 34.661 | 33.99 | 2.07 | 2.33 | < 0.02 | 0.02 | 82.97 |
| 18 | 550.1 | 184.00 | 34.700 | 32.96 | 1.99 | 2.27 | < 0.02 | < 0.02 | 85.19 |
| 19 | 550.2 | < 0.02 | < 0.02 | < 0.02 | 1.99 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 799.8 | 192.85 | 34.730 | 31.98 | 1.85 | 2.20 | < 0.02 | < 0.02 | 89.01 |
| 15 | 1099.5 | 200.84 | 34.740 | 31.55 | 1.61 | 2.18 | < 0.02 | < 0.02 | 94.96 |
| 16 | 1099.6 | < 0.02 | < 0.02 | < 0.02 | 1.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 1549.9 | 206.96 | 34.727 | 31.92 | 1.22 | 2.21 | < 0.02 | < 0.02 | 105.95 |
| 14 | 1550 | < 0.02 | < 0.02 | < 0.02 | 1.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 2050.3 | < 0.02 | < 0.02 | < 0.02 | 0.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 2050.3 | 211.11 | 34.709 | 32.45 | 0.87 | 2.26 | < 0.02 | < 0.02 | 116.54 |
| 10 | 2550 | 218.21 | 34.692 | 32.89 | 0.53 | 2.29 | < 0.02 | < 0.02 | 125.92 |
| 8 | 3030.1 | 224.56 | 34.680 | 33.07 | 0.31 | 2.30 | < 0.02 | < 0.02 | 131.16 |
| 9 | 3030.1 | < 0.02 | < 0.02 | < 0.02 | 0.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 3499.9 | 230.00 | 34.672 | 33.06 | 0.16 | 2.30 | < 0.02 | < 0.02 | 132.85 |
| 5 | 4000.2 | 238.98 | 34.660 | 32.77 | -0.02 | 2.28 | < 0.02 | < 0.02 | 122.70 |
| 6 | 4000.3 | < 0.02 | < 0.02 | < 0.02 | -0.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 4340.5 | 253.45 | 34.641 | 32.41 | -0.30 | 2.26 | < 0.02 | < 0.02 | 106.11 |
| 2 | 4376.5 | < 0.02 | < 0.02 | < 0.02 | -0.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 4376.7 | < 0.02 | < 0.02 | < 0.02 | -0.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 4376.7 | 255.51 | 34.639 | 32.37 | -0.36 | 2.25 | < 0.02 | 0.02 | 105.17 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
| Chlorophyll - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 25 - SN 4774 | Seabird | SBE4C | 4774 | |
| Licor - CTD 25 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 25-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Turbidity (%) |
| Temperature CTD 25-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 25 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |