Please login if you have access to particular applications.
Deployment Details
Survey: - IN2024_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 21
Gear: Autosal Salinometer,CTD 25 - SN 1354,Chlorophyll - CTD 25 - Wetlabs ECO,Conductivity CTD 25 - SN 4774,Licor - CTD 25 - SN 70562,Oxygen CTD 25-SBE 43-SN 3155,Pressure CTD 25,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 25 - Wetlabs ECO,Temperature CTD 25-SN 2751,Transmissometer - CTD 25 -CST-1421DR
When: 2024-01-22 13:24 to 2024-01-22 16:24 UTC
Where: 63° 21.1' S 140° 00.3' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 36 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 1.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 6.4 | 359.39 | 33.779 | 23.81 | 1.01 | 1.43 | 0.06 | 0.27 | 21.98 |
| 33 | 30.3 | 359.12 | 33.779 | 23.86 | 1.01 | 1.45 | 0.07 | 0.27 | 22.01 |
| 34 | 30.4 | < 0.02 | < 0.02 | < 0.02 | 1.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 55.1 | < 0.02 | < 0.02 | < 0.02 | 0.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 55.1 | 350.14 | 33.846 | 25.79 | 0.29 | 1.81 | 0.92 | 0.24 | 30.96 |
| 32 | 55.2 | < 0.02 | < 0.02 | < 0.02 | 0.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 65.4 | < 0.02 | < 0.02 | < 0.02 | -0.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 65.4 | 335.40 | 33.984 | 28.36 | -0.76 | 2.05 | 1.01 | 0.19 | 43.34 |
| 29 | 65.5 | < 0.02 | < 0.02 | < 0.02 | -0.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 85.3 | 315.71 | 34.139 | 31.03 | -1.15 | 2.23 | 0.89 | 0.18 | 53.50 |
| 24 | 120.1 | 285.74 | 34.303 | 32.89 | -0.70 | 2.29 | < 0.02 | 0.16 | 61.84 |
| 25 | 120.1 | < 0.02 | < 0.02 | < 0.02 | -0.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 160.3 | 245.46 | 34.433 | 32.99 | -0.05 | 2.28 | < 0.02 | 0.02 | 70.72 |
| 23 | 160.4 | < 0.02 | < 0.02 | < 0.02 | -0.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 205.6 | 231.70 | 34.510 | 32.87 | 0.47 | 2.28 | < 0.02 | < 0.02 | 76.42 |
| 20 | 281.1 | 213.97 | 34.607 | 32.55 | 0.99 | 2.25 | < 0.02 | < 0.02 | 83.06 |
| 19 | 450.3 | < 0.02 | < 0.02 | < 0.02 | 1.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 450.4 | 203.65 | 34.697 | 31.84 | 1.36 | 2.21 | < 0.02 | < 0.02 | 90.02 |
| 17 | 600.1 | 206.83 | 34.706 | 31.64 | 1.26 | 2.20 | < 0.02 | < 0.02 | 93.17 |
| 16 | 800.7 | 209.06 | 34.713 | 31.65 | 1.16 | 2.20 | < 0.02 | < 0.02 | 99.27 |
| 15 | 1100.2 | 210.58 | 34.712 | 31.84 | 1.01 | 2.22 | < 0.02 | < 0.02 | 106.11 |
| 14 | 1500.4 | 213.97 | 34.702 | 32.33 | 0.76 | 2.25 | < 0.02 | < 0.02 | 113.98 |
| 13 | 1800.3 | 216.61 | 34.693 | 32.60 | 0.59 | 2.26 | < 0.02 | < 0.02 | 119.09 |
| 12 | 2100.5 | 220.45 | 34.687 | 32.69 | 0.44 | 2.28 | < 0.02 | < 0.02 | 122.94 |
| 11 | 2400.4 | 223.71 | 34.682 | 32.71 | 0.31 | 2.28 | < 0.02 | < 0.02 | 126.72 |
| 10 | 2700.2 | 227.73 | 34.676 | 32.64 | 0.20 | 2.28 | < 0.02 | < 0.02 | 127.67 |
| 9 | 3000.5 | 232.95 | 34.670 | 32.61 | 0.07 | 2.28 | < 0.02 | < 0.02 | 127.79 |
| 8 | 3300.6 | 239.56 | 34.660 | 32.43 | -0.08 | 2.26 | < 0.02 | < 0.02 | 119.28 |
| 7 | 3501 | 244.34 | 34.656 | 32.33 | -0.19 | 2.25 | < 0.02 | < 0.02 | 113.07 |
| 5 | 3601.5 | 248.27 | 34.650 | 32.19 | -0.27 | 2.25 | < 0.02 | < 0.02 | 108.52 |
| 6 | 3601.8 | < 0.02 | < 0.02 | < 0.02 | -0.27 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 3801 | 255.42 | 34.639 | 32.05 | -0.42 | 2.24 | < 0.02 | < 0.02 | 104.76 |
| 4 | 3801.3 | < 0.02 | < 0.02 | < 0.02 | -0.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 3838.2 | 256.35 | 34.639 | 32.11 | -0.42 | 2.24 | < 0.02 | < 0.02 | 104.80 |
| 2 | 3838.4 | < 0.02 | < 0.02 | < 0.02 | -0.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
| Chlorophyll - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 25 - SN 4774 | Seabird | SBE4C | 4774 | |
| Licor - CTD 25 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 25-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Turbidity (%) |
| Temperature CTD 25-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 25 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |