Please login if you have access to particular applications.
Deployment Details
Survey: - IN2024_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 18
Gear: Autosal Salinometer,CTD 25 - SN 1354,Chlorophyll - CTD 25 - Wetlabs ECO,Conductivity CTD 25 - SN 4774,Licor - CTD 25 - SN 70562,Oxygen CTD 25-SBE 43-SN 3155,Pressure CTD 25,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 25 - Wetlabs ECO,Temperature CTD 25-SN 2751,Transmissometer - CTD 25 -CST-1421DR
When: 2024-01-21 15:04 to 2024-01-21 17:38 UTC
Where: 64° 32.9' S 140° 00.3' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 35 | 8.1 | 353.67 | 33.494 | 26.81 | 0.23 | 1.82 | 0.51 | 0.26 | 44.44 |
| 36 | 8.2 | < 0.02 | < 0.02 | < 0.02 | 0.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 25.5 | 353.49 | 33.502 | 26.79 | 0.23 | 1.82 | 0.52 | 0.26 | 44.45 |
| 34 | 25.6 | < 0.02 | < 0.02 | < 0.02 | 0.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 55.3 | < 0.02 | < 0.02 | < 0.02 | -1.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 55.3 | 335.94 | 34.034 | 29.13 | -1.16 | 2.04 | 0.54 | 0.17 | 52.63 |
| 29 | 85.3 | 313.16 | 34.212 | 30.64 | -1.35 | 2.13 | 0.37 | 0.15 | 59.25 |
| 30 | 85.4 | < 0.02 | < 0.02 | < 0.02 | -1.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 110.1 | 294.45 | 34.320 | 31.60 | -1.20 | 2.19 | 0.15 | 0.14 | 64.80 |
| 27 | 150.5 | 267.03 | 34.429 | 32.24 | -0.57 | 2.22 | < 0.02 | 0.06 | 72.38 |
| 26 | 200.4 | 246.89 | 34.510 | 32.47 | -0.04 | 2.23 | < 0.02 | 0.03 | 77.87 |
| 25 | 280.2 | 215.44 | 34.645 | 32.29 | 0.91 | 2.22 | < 0.02 | 0.02 | 86.94 |
| 24 | 360.7 | 208.83 | 34.694 | 31.98 | 1.18 | 2.20 | < 0.02 | 0.02 | 92.04 |
| 23 | 440.6 | 209.06 | 34.701 | 31.89 | 1.15 | 2.20 | < 0.02 | 0.02 | 94.89 |
| 21 | 550.2 | 210.35 | 34.706 | 31.91 | 1.03 | 2.20 | < 0.02 | 0.02 | 99.82 |
| 22 | 550.3 | < 0.02 | < 0.02 | < 0.02 | 1.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 670.4 | 212.23 | 34.701 | 32.11 | 0.92 | 2.22 | < 0.02 | < 0.02 | 103.42 |
| 19 | 790.6 | 211.74 | 34.705 | 32.15 | 0.88 | 2.22 | < 0.02 | 0.02 | 107.06 |
| 17 | 930.6 | 212.36 | 34.704 | 32.34 | 0.80 | 2.23 | < 0.02 | < 0.02 | 110.84 |
| 18 | 930.8 | < 0.02 | < 0.02 | < 0.02 | 0.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 1100.4 | 215.22 | 34.693 | 32.50 | 0.64 | 2.25 | < 0.02 | < 0.02 | 113.34 |
| 15 | 1301.1 | 217.86 | 34.687 | 32.67 | 0.50 | 2.26 | < 0.02 | < 0.02 | 116.83 |
| 14 | 1500.4 | 219.06 | 34.686 | 32.75 | 0.41 | 2.27 | < 0.02 | < 0.02 | 121.38 |
| 13 | 1791.3 | 224.42 | 34.678 | 32.84 | 0.22 | 2.28 | < 0.02 | < 0.02 | 123.00 |
| 12 | 2100.3 | 229.56 | 34.674 | 32.82 | 0.07 | 2.29 | < 0.02 | < 0.02 | 128.21 |
| 11 | 2291.7 | 233.98 | 34.667 | 32.76 | -0.04 | 2.28 | < 0.02 | < 0.02 | 122.46 |
| 10 | 2450.4 | 236.97 | 34.664 | 32.74 | -0.11 | 2.28 | < 0.02 | < 0.02 | 122.70 |
| 9 | 2590.7 | 240.54 | 34.660 | 32.66 | -0.18 | 2.27 | < 0.02 | < 0.02 | 118.51 |
| 8 | 2750.3 | 245.28 | 34.655 | 32.42 | -0.29 | 2.26 | < 0.02 | < 0.02 | 108.90 |
| 7 | 2901 | 252.33 | 34.644 | 32.30 | -0.43 | 2.25 | < 0.02 | < 0.02 | 104.83 |
| 5 | 3000.7 | 256.04 | 34.640 | 32.24 | -0.48 | 2.25 | < 0.02 | 0.02 | 102.98 |
| 6 | 3000.9 | < 0.02 | < 0.02 | < 0.02 | -0.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 3051 | 256.53 | 34.640 | 32.26 | -0.49 | 2.25 | < 0.02 | 0.02 | 103.06 |
| 4 | 3051.4 | < 0.02 | < 0.02 | < 0.02 | -0.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 3108.7 | < 0.02 | < 0.02 | < 0.02 | -0.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 3108.7 | 255.59 | 34.646 | 32.28 | -0.49 | 2.26 | < 0.02 | 0.02 | 103.27 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
| Chlorophyll - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 25 - SN 4774 | Seabird | SBE4C | 4774 | |
| Licor - CTD 25 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 25-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Turbidity (%) |
| Temperature CTD 25-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 25 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |