Please login if you have access to particular applications.
Deployment Details
Survey: - IN2024_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 17
Gear: Autosal Salinometer,CTD 25 - SN 1354,Chlorophyll - CTD 25 - Wetlabs ECO,Conductivity CTD 25 - SN 4774,Licor - CTD 25 - SN 70562,Oxygen CTD 25-SBE 43-SN 3155,Pressure CTD 25,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 25 - Wetlabs ECO,Temperature CTD 25-SN 2751,Transmissometer - CTD 25 -CST-1421DR
When: 2024-01-21 04:58 to 2024-01-21 07:15 UTC
Where: 65° 00.0' S 140° 00.3' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 35 | 4.5 | 352.73 | 33.734 | 27.48 | -0.03 | 1.85 | 0.31 | 0.23 | 46.71 |
| 36 | 4.5 | < 0.02 | < 0.02 | < 0.02 | -0.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 20.1 | 353.00 | 33.734 | 27.48 | -0.05 | 1.86 | 0.32 | 0.28 | 46.67 |
| 34 | 20.1 | < 0.02 | < 0.02 | < 0.02 | -0.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 30.1 | 349.38 | 33.820 | 27.92 | -0.45 | 1.90 | 0.29 | 0.23 | 49.07 |
| 30 | 65.1 | 309.37 | 34.304 | 31.11 | -1.55 | 2.15 | 0.13 | 0.18 | 63.96 |
| 31 | 65.1 | < 0.02 | < 0.02 | < 0.02 | -1.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 74.9 | < 0.02 | < 0.02 | < 0.02 | -1.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 74.9 | 302.80 | 34.326 | 31.48 | -1.50 | 2.17 | 0.07 | 0.18 | 65.53 |
| 27 | 120 | 292.66 | 34.391 | 31.76 | -1.35 | 2.18 | < 0.02 | 0.07 | 70.11 |
| 26 | 220.2 | 235.94 | 34.581 | 32.28 | 0.20 | 2.22 | < 0.02 | 0.05 | 85.18 |
| 25 | 339.9 | 215.36 | 34.673 | 32.17 | 0.85 | 2.22 | < 0.02 | 0.04 | 94.04 |
| 23 | 425.1 | 211.51 | 34.693 | 32.16 | 0.97 | 2.22 | < 0.02 | 0.04 | 97.38 |
| 24 | 425.2 | < 0.02 | < 0.02 | < 0.02 | 0.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 650.4 | 211.87 | 34.702 | 32.37 | 0.85 | 2.24 | < 0.02 | 0.03 | 105.78 |
| 22 | 650.4 | < 0.02 | < 0.02 | < 0.02 | 0.86 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 799.5 | 213.08 | 34.694 | 32.58 | 0.72 | 2.25 | < 0.02 | 0.03 | 109.90 |
| 18 | 1000.3 | 215.22 | 34.688 | 32.84 | 0.57 | 2.27 | < 0.02 | 0.03 | 114.20 |
| 19 | 1000.4 | < 0.02 | < 0.02 | < 0.02 | 0.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 1200.3 | 216.78 | 34.691 | 32.92 | 0.51 | 2.28 | < 0.02 | 0.03 | 119.14 |
| 16 | 1400.6 | 200.75 | 34.684 | 33.03 | 0.36 | 2.29 | < 0.02 | 0.02 | 121.20 |
| 15 | 1600.6 | 222.86 | 34.681 | 33.04 | 0.26 | 2.29 | < 0.02 | 0.03 | 124.08 |
| 14 | 1800.3 | 226.65 | 34.677 | 32.99 | 0.15 | 2.29 | < 0.02 | 0.02 | 121.39 |
| 12 | 2120.4 | 235.10 | 34.664 | 32.84 | -0.06 | 2.28 | < 0.02 | 0.02 | 116.15 |
| 13 | 2120.5 | < 0.02 | < 0.02 | < 0.02 | -0.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 2300.3 | 237.95 | 34.665 | 32.74 | -0.11 | 2.27 | < 0.02 | 0.02 | 113.24 |
| 11 | 2300.4 | < 0.02 | < 0.02 | < 0.02 | -0.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 2379.9 | 244.97 | 34.657 | 32.57 | -0.26 | 2.26 | < 0.02 | 0.02 | 107.50 |
| 9 | 2380 | < 0.02 | < 0.02 | < 0.02 | -0.27 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 2500.4 | 246.08 | 34.652 | 32.51 | -0.29 | 2.26 | < 0.02 | 0.02 | 106.83 |
| 6 | 2550.6 | 246.44 | 34.651 | 32.52 | -0.30 | 2.26 | < 0.02 | 0.02 | 106.20 |
| 5 | 2600.6 | 247.91 | 34.650 | 32.46 | -0.34 | 2.25 | < 0.02 | 0.02 | 105.00 |
| 3 | 2650.3 | 258.19 | 34.651 | 32.47 | -0.34 | 2.26 | < 0.02 | < 0.02 | 104.90 |
| 4 | 2650.3 | < 0.02 | < 0.02 | < 0.02 | -0.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 2700.3 | 261.13 | 34.651 | 32.46 | -0.33 | 2.26 | < 0.02 | 0.02 | 104.94 |
| 2 | 2700.4 | < 0.02 | < 0.02 | < 0.02 | -0.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
| Chlorophyll - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 25 - SN 4774 | Seabird | SBE4C | 4774 | |
| Licor - CTD 25 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 25-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Turbidity (%) |
| Temperature CTD 25-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 25 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |