Please login if you have access to particular applications.
Deployment Details
Survey: - IN2024_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 12
Gear: Autosal Salinometer,CTD 25 - SN 1354,Chlorophyll - CTD 25 - Wetlabs ECO,Conductivity CTD 25 - SN 4774,Licor - CTD 25 - SN 70562,Oxygen CTD 25-SBE 43-SN 3155,Pressure CTD 25,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 25 - Wetlabs ECO,Temperature CTD 25-SN 2751,Transmissometer - CTD 25 -CST-1421DR
When: 2024-01-15 21:07 to 2024-01-15 22:23 UTC
Where: 67° 00.1' S 145° 00.1' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 34 | 5 | 412.31 | 33.977 | 20.81 | -1.31 | 1.48 | 0.19 | 0.11 | 71.82 |
| 35 | 5 | < 0.02 | < 0.02 | < 0.02 | -1.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 5 | < 0.02 | < 0.02 | < 0.02 | -1.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 10.1 | < 0.02 | < 0.02 | < 0.02 | -1.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 10.1 | 389.94 | 33.978 | 20.79 | -1.32 | 1.48 | 0.20 | 0.11 | 71.83 |
| 30 | 20.3 | 388.24 | 33.996 | 20.97 | -1.32 | 1.51 | 0.26 | 0.11 | 72.05 |
| 31 | 20.3 | < 0.02 | < 0.02 | < 0.02 | -1.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 30.4 | 361.08 | 34.269 | 25.17 | -1.29 | 1.80 | 0.64 | 0.10 | 76.40 |
| 28 | 45.3 | 348.04 | 34.339 | 27.25 | -1.35 | 1.94 | 0.75 | 0.10 | 78.17 |
| 26 | 60.4 | < 0.02 | < 0.02 | < 0.02 | -1.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 60.4 | 334.96 | 34.387 | 28.82 | -1.53 | 2.08 | 1.15 | 0.08 | 79.62 |
| 27 | 60.4 | < 0.02 | < 0.02 | < 0.02 | -1.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 75.2 | 329.42 | 34.411 | 29.89 | -1.64 | 2.11 | 0.64 | 0.08 | 80.17 |
| 21 | 100.6 | 332.64 | 34.420 | 30.21 | -1.69 | 2.11 | 0.46 | 0.09 | 80.01 |
| 22 | 100.6 | < 0.02 | < 0.02 | < 0.02 | -1.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 100.6 | < 0.02 | < 0.02 | < 0.02 | -1.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 200.6 | < 0.02 | < 0.02 | < 0.02 | -1.73 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 200.6 | < 0.02 | < 0.02 | < 0.02 | -1.73 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 200.6 | 327.90 | 34.438 | 30.62 | -1.73 | 2.12 | 0.25 | 0.10 | 80.17 |
| 17 | 310.8 | 315.40 | 34.465 | 31.16 | -1.76 | 2.14 | < 0.02 | 0.09 | 81.01 |
| 15 | 425.6 | 310.66 | 34.512 | 31.34 | -1.82 | 2.15 | < 0.02 | 0.03 | 81.34 |
| 16 | 425.7 | < 0.02 | < 0.02 | < 0.02 | -1.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 575.4 | < 0.02 | < 0.02 | < 0.02 | -2.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 575.4 | 316.02 | 34.559 | 31.43 | -2.05 | 2.16 | < 0.02 | < 0.02 | 80.93 |
| 11 | 675.5 | 315.04 | 34.579 | 31.40 | -2.01 | 2.16 | < 0.02 | < 0.02 | 81.03 |
| 12 | 675.6 | < 0.02 | < 0.02 | < 0.02 | -2.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 791 | 314.37 | 34.603 | 31.45 | -1.92 | 2.16 | < 0.02 | < 0.02 | 80.99 |
| 8 | 900.9 | 315.66 | 34.624 | 31.43 | -1.89 | 2.16 | < 0.02 | 0.02 | 80.95 |
| 9 | 901 | < 0.02 | < 0.02 | < 0.02 | -1.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 1050.5 | < 0.02 | < 0.02 | < 0.02 | -1.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 1050.5 | 315.17 | 34.632 | 31.45 | -1.88 | 2.16 | < 0.02 | < 0.02 | 81.13 |
| 4 | 1100.4 | 315.57 | 34.634 | 31.46 | -1.88 | 2.16 | < 0.02 | < 0.02 | 81.12 |
| 5 | 1100.6 | < 0.02 | < 0.02 | < 0.02 | -1.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 1146.1 | 315.49 | 34.634 | 31.44 | -1.88 | 2.16 | < 0.02 | < 0.02 | 81.16 |
| 2 | 1146.2 | < 0.02 | < 0.02 | < 0.02 | -1.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 1146.2 | < 0.02 | < 0.02 | < 0.02 | -1.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
| Chlorophyll - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 25 - SN 4774 | Seabird | SBE4C | 4774 | |
| Licor - CTD 25 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 25-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Turbidity (%) |
| Temperature CTD 25-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 25 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |