Please login if you have access to particular applications.
Deployment Details
Survey: - IN2024_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 10
Gear: Autosal Salinometer,CTD 25 - SN 1354,Chlorophyll - CTD 25 - Wetlabs ECO,Conductivity CTD 25 - SN 4774,Licor - CTD 25 - SN 70562,Oxygen CTD 25-SBE 43-SN 3155,Pressure CTD 25,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 25 - Wetlabs ECO,Temperature CTD 25-SN 2751,Transmissometer - CTD 25 -CST-1421DR
When: 2024-01-14 11:43 to 2024-01-14 12:32 UTC
Where: 66° 28.6' S 144° 56.9' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 35 | 3.3 | 395.03 | 33.831 | 19.28 | -0.68 | 1.30 | 0.09 | 0.15 | 63.33 |
| 36 | 3.4 | < 0.02 | < 0.02 | < 0.02 | -0.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 15.1 | < 0.02 | < 0.02 | < 0.02 | -0.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 15.1 | < 0.02 | < 0.02 | < 0.02 | -0.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 15.2 | 397.53 | 33.842 | 19.25 | -0.67 | 1.30 | 0.11 | 0.15 | 63.67 |
| 31 | 20.2 | 389.00 | 34.009 | 20.57 | -0.79 | 1.45 | 0.31 | 0.12 | 66.57 |
| 30 | 32 | < 0.02 | < 0.02 | < 0.02 | -1.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 32.1 | < 0.02 | < 0.02 | < 0.02 | -1.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 32.1 | 346.17 | 34.299 | 27.93 | -1.30 | 1.94 | 0.57 | 0.11 | 75.05 |
| 26 | 45.1 | < 0.02 | < 0.02 | < 0.02 | -1.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 45.1 | 332.86 | 34.373 | 29.35 | -1.46 | 2.03 | 0.53 | 0.10 | 77.93 |
| 27 | 45.1 | < 0.02 | < 0.02 | < 0.02 | -1.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 75.2 | 313.83 | 34.460 | 30.83 | -1.59 | 2.11 | 0.18 | 0.09 | 81.31 |
| 23 | 75.2 | < 0.02 | < 0.02 | < 0.02 | -1.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 75.3 | < 0.02 | < 0.02 | < 0.02 | -1.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 100.1 | 312.94 | 34.465 | 30.90 | -1.59 | 2.11 | 0.16 | 0.08 | 81.42 |
| 21 | 100.2 | < 0.02 | < 0.02 | < 0.02 | -1.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 120.1 | < 0.02 | < 0.02 | < 0.02 | -1.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 120.1 | 311.64 | 34.473 | 30.97 | -1.60 | 2.11 | 0.12 | 0.08 | 81.65 |
| 16 | 150.3 | < 0.02 | < 0.02 | < 0.02 | -1.62 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 150.3 | < 0.02 | < 0.02 | < 0.02 | -1.62 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 150.3 | 305.88 | 34.498 | 31.28 | -1.62 | 2.13 | 0.03 | 0.06 | 82.54 |
| 14 | 200.4 | 304.68 | 34.523 | 31.38 | -1.66 | 2.14 | < 0.02 | 0.05 | 82.78 |
| 13 | 224.5 | 304.32 | 34.536 | 31.40 | -1.68 | 2.15 | < 0.02 | 0.04 | 82.75 |
| 11 | 250.3 | 304.81 | 34.546 | 31.44 | -1.71 | 2.15 | < 0.02 | 0.03 | 82.77 |
| 12 | 250.4 | < 0.02 | < 0.02 | < 0.02 | -1.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 300.2 | 305.75 | 34.560 | 31.48 | -1.77 | 2.15 | < 0.02 | 0.02 | 82.60 |
| 9 | 335.3 | 306.15 | 34.571 | 31.51 | -1.79 | 2.15 | < 0.02 | 0.02 | 82.64 |
| 7 | 349.8 | 307.00 | 34.587 | 31.47 | -1.81 | 2.15 | < 0.02 | 0.02 | 82.67 |
| 8 | 349.8 | < 0.02 | < 0.02 | < 0.02 | -1.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 375.2 | 308.34 | 34.603 | 31.45 | -1.87 | 2.16 | < 0.02 | 0.03 | 83.05 |
| 4 | 400.3 | 309.14 | 34.606 | 31.45 | -1.87 | 2.15 | < 0.02 | 0.03 | 83.06 |
| 5 | 400.4 | < 0.02 | < 0.02 | < 0.02 | -1.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 419.4 | 308.74 | 34.606 | 31.46 | -1.87 | 2.16 | < 0.02 | 0.03 | 83.12 |
| 2 | 419.4 | < 0.02 | < 0.02 | < 0.02 | -1.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 419.4 | < 0.02 | < 0.02 | < 0.02 | -1.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
| Chlorophyll - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 25 - SN 4774 | Seabird | SBE4C | 4774 | |
| Licor - CTD 25 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 25-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Turbidity (%) |
| Temperature CTD 25-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 25 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |