Please login if you have access to particular applications.
Deployment Details
Survey: - IN2024_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 9
Gear: Autosal Salinometer,CTD 25 - SN 1354,Chlorophyll - CTD 25 - Wetlabs ECO,Conductivity CTD 25 - SN 4774,Licor - CTD 25 - SN 70562,Oxygen CTD 25-SBE 43-SN 3155,Pressure CTD 25,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 25 - Wetlabs ECO,Temperature CTD 25-SN 2751,Transmissometer - CTD 25 -CST-1421DR
When: 2024-01-13 04:57 to 2024-01-13 07:28 UTC
Where: 65° 20.5' S 150° 00.2' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 35 | 4.3 | < 0.02 | < 0.02 | < 0.02 | -1.62 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 4.5 | 360.55 | 33.167 | 27.22 | -1.62 | 1.81 | 0.37 | 0.21 | 48.23 |
| 33 | 4.6 | 360.06 | 33.180 | 27.21 | -1.62 | 1.81 | 0.37 | 0.22 | 48.16 |
| 34 | 4.6 | < 0.02 | < 0.02 | < 0.02 | -1.62 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 15 | 356.26 | 33.567 | 27.84 | -1.25 | 1.87 | 0.35 | 0.20 | 52.89 |
| 30 | 30.8 | 346.21 | 33.825 | 28.65 | -1.40 | 1.94 | 0.33 | 0.17 | 56.09 |
| 31 | 30.9 | < 0.02 | < 0.02 | < 0.02 | -1.40 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 45 | 329.42 | 34.086 | 29.81 | -1.60 | 2.04 | 0.27 | 0.13 | 62.09 |
| 29 | 45.1 | < 0.02 | < 0.02 | < 0.02 | -1.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 60.2 | 316.69 | 34.185 | 30.59 | -1.72 | 2.10 | 0.23 | 0.12 | 66.53 |
| 27 | 60.3 | < 0.02 | < 0.02 | < 0.02 | -1.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 80.3 | 302.35 | 34.279 | 31.35 | -1.70 | 2.15 | 0.09 | 0.12 | 72.60 |
| 24 | 114.9 | 296.68 | 34.358 | 31.42 | -1.66 | 2.13 | < 0.02 | 0.06 | 78.30 |
| 22 | 150.2 | 291.90 | 34.413 | 31.49 | -1.48 | 2.15 | < 0.02 | 0.03 | 80.40 |
| 23 | 150.3 | < 0.02 | < 0.02 | < 0.02 | -1.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 210.1 | 234.92 | 34.570 | 32.44 | 0.26 | 2.21 | < 0.02 | 0.02 | 84.33 |
| 19 | 348.5 | 212.01 | 34.677 | 32.26 | 1.02 | 2.20 | < 0.02 | < 0.02 | 92.12 |
| 20 | 348.5 | < 0.02 | < 0.02 | < 0.02 | 1.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 480.5 | < 0.02 | < 0.02 | < 0.02 | 1.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 480.5 | 208.34 | 34.708 | 32.07 | 1.16 | 2.20 | < 0.02 | < 0.02 | 97.34 |
| 15 | 750.3 | 209.50 | 34.711 | 32.31 | 1.01 | 2.22 | < 0.02 | < 0.02 | 105.67 |
| 16 | 750.3 | < 0.02 | < 0.02 | < 0.02 | 1.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 1049.9 | < 0.02 | < 0.02 | < 0.02 | 0.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 1049.9 | 212.36 | 34.702 | 32.68 | 0.78 | 2.25 | < 0.02 | < 0.02 | 113.87 |
| 12 | 1350 | 214.91 | 34.690 | 33.10 | 0.54 | 2.28 | < 0.02 | < 0.02 | 119.25 |
| 11 | 1650.4 | 220.36 | 34.686 | 33.16 | 0.36 | 2.28 | < 0.02 | < 0.02 | 121.08 |
| 10 | 1950.8 | 223.89 | 34.679 | 33.17 | 0.23 | 2.28 | < 0.02 | < 0.02 | 121.98 |
| 8 | 2250.5 | 230.09 | 34.673 | 33.15 | 0.08 | 2.28 | < 0.02 | < 0.02 | 124.62 |
| 9 | 2250.6 | < 0.02 | < 0.02 | < 0.02 | 0.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 2649.7 | 238.58 | 34.665 | 32.99 | -0.12 | 2.26 | < 0.02 | < 0.02 | 119.77 |
| 6 | 2850.9 | 241.21 | 34.672 | 32.68 | -0.20 | 2.26 | < 0.02 | < 0.02 | 107.17 |
| 4 | 2920.4 | 241.93 | 34.673 | 32.65 | -0.22 | 2.26 | < 0.02 | 0.02 | 106.37 |
| 5 | 2920.4 | < 0.02 | < 0.02 | < 0.02 | -0.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 2969.9 | < 0.02 | < 0.02 | < 0.02 | -0.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 2970 | 242.11 | 34.676 | 32.66 | -0.23 | 2.24 | < 0.02 | 0.02 | 105.89 |
| 3 | 2970 | < 0.02 | < 0.02 | < 0.02 | -0.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
| Chlorophyll - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 25 - SN 4774 | Seabird | SBE4C | 4774 | |
| Licor - CTD 25 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 25-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Turbidity (%) |
| Temperature CTD 25-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 25 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |