Please login if you have access to particular applications.
Deployment Details
Survey: - IN2024_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 7
Gear: Autosal Salinometer,CTD 25 - SN 1354,Chlorophyll - CTD 25 - Wetlabs ECO,Conductivity CTD 25 - SN 4774,Licor - CTD 25 - SN 70562,Oxygen CTD 25-SBE 43-SN 3155,Pressure CTD 25,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 25 - Wetlabs ECO,Temperature CTD 25-SN 2751,Transmissometer - CTD 25 -CST-1421DR
When: 2024-01-12 04:00 to 2024-01-12 06:34 UTC
Where: 64° 30.0' S 150° 00.0' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 34 | 5 | 356.84 | 33.809 | 26.97 | 0.43 | 1.73 | 0.36 | 0.24 | 38.08 |
| 35 | 5 | < 0.02 | < 0.02 | < 0.02 | 0.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 5 | < 0.02 | < 0.02 | < 0.02 | 0.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 14.7 | 356.66 | 33.810 | 27.04 | 0.35 | 1.75 | 0.39 | 0.24 | 38.71 |
| 32 | 40.1 | 354.79 | 33.823 | 27.31 | 0.07 | 1.79 | 0.56 | 0.22 | 40.59 |
| 31 | 59.5 | 315.40 | 34.094 | 30.50 | -0.91 | 2.17 | 0.82 | 0.18 | 53.45 |
| 30 | 59.5 | < 0.02 | < 0.02 | < 0.02 | -0.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 59.5 | < 0.02 | < 0.02 | < 0.02 | -0.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 105.1 | < 0.02 | < 0.02 | < 0.02 | 0.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 105.1 | < 0.02 | < 0.02 | < 0.02 | 0.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 105.1 | 219.78 | 34.463 | 34.09 | 0.80 | 2.36 | 0.08 | 0.14 | 73.24 |
| 25 | 225.5 | < 0.02 | < 0.02 | < 0.02 | 1.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 225.5 | < 0.02 | < 0.02 | < 0.02 | 1.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 225.6 | 183.51 | 34.661 | 33.57 | 1.84 | 2.31 | < 0.02 | 0.02 | 84.13 |
| 21 | 505.1 | 195.70 | 34.720 | 31.91 | 1.70 | 2.19 | < 0.02 | 0.02 | 89.20 |
| 22 | 505.2 | < 0.02 | < 0.02 | < 0.02 | 1.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 750.7 | 201.29 | 34.733 | 31.48 | 1.51 | 2.17 | < 0.02 | < 0.02 | 95.22 |
| 20 | 750.8 | < 0.02 | < 0.02 | < 0.02 | 1.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 1005.6 | 206.87 | 34.725 | 31.56 | 1.25 | 2.18 | < 0.02 | < 0.02 | 101.00 |
| 17 | 1005.6 | < 0.02 | < 0.02 | < 0.02 | 1.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 1250.3 | 210.00 | 34.717 | 31.77 | 1.07 | 2.20 | < 0.02 | < 0.02 | 106.70 |
| 14 | 1506.1 | 211.74 | 34.710 | 32.13 | 0.87 | 2.23 | < 0.02 | < 0.02 | 114.17 |
| 15 | 1506.3 | < 0.02 | < 0.02 | < 0.02 | 0.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 2001 | 217.86 | 34.693 | 32.57 | 0.54 | 2.27 | < 0.02 | < 0.02 | 122.90 |
| 13 | 2001.2 | < 0.02 | < 0.02 | < 0.02 | 0.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 2451.3 | 224.15 | 34.679 | 32.67 | 0.28 | 2.28 | < 0.02 | < 0.02 | 123.58 |
| 9 | 2750.1 | 228.89 | 34.675 | 32.63 | 0.16 | 2.28 | < 0.02 | < 0.02 | 124.67 |
| 10 | 2750.3 | < 0.02 | < 0.02 | < 0.02 | 0.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 3150.5 | 236.84 | 34.668 | 32.46 | -0.02 | 2.27 | < 0.02 | < 0.02 | 118.93 |
| 7 | 3150.7 | < 0.02 | < 0.02 | < 0.02 | -0.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 3150.7 | < 0.02 | < 0.02 | < 0.02 | -0.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 3400.4 | 241.57 | 34.665 | 32.32 | -0.14 | 2.26 | < 0.02 | < 0.02 | 111.78 |
| 5 | 3400.5 | < 0.02 | < 0.02 | < 0.02 | -0.14 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 3524.5 | 245.37 | 34.660 | 32.24 | -0.24 | 2.26 | < 0.02 | < 0.02 | 109.91 |
| 2 | 3524.6 | < 0.02 | < 0.02 | < 0.02 | -0.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 3524.7 | < 0.02 | < 0.02 | < 0.02 | -0.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
| Chlorophyll - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 25 - SN 4774 | Seabird | SBE4C | 4774 | |
| Licor - CTD 25 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 25-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Turbidity (%) |
| Temperature CTD 25-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 25 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |