Please login if you have access to particular applications.
Deployment Details
Survey: - IN2024_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 1
Gear: Autosal Salinometer,CTD 25 - SN 1354,Chlorophyll - CTD 25 - Wetlabs ECO,Conductivity CTD 25 - SN 4774,Licor - CTD 25 - SN 70562,Oxygen CTD 25-SBE 43-SN 3155,Pressure CTD 25,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 25 - Wetlabs ECO,Temperature CTD 25-SN 2751,Transmissometer - CTD 25 -CST-1421DR
When: 2024-01-02 08:21 to 2024-01-02 09:31 UTC
Where: 43° 33.0' S 148° 07.0' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 998.3 | 180.56 | 34.457 | 32.87 | 4.43 | 2.26 | < 0.02 | < 0.02 | 52.65 |
| 2 | 998.6 | 179.89 | 34.456 | 32.89 | 4.44 | 2.26 | < 0.02 | < 0.02 | 52.52 |
| 3 | 998.6 | 180.74 | 34.456 | 32.87 | 4.44 | 2.27 | < 0.02 | < 0.02 | 52.50 |
| 10 | 998.7 | 180.48 | 34.456 | 32.83 | 4.44 | 2.26 | < 0.02 | < 0.02 | 52.27 |
| 12 | 998.7 | 180.48 | 34.456 | 32.93 | 4.44 | 2.26 | < 0.02 | < 0.02 | 52.21 |
| 25 | 998.7 | 180.56 | 34.456 | 32.86 | 4.43 | 2.26 | < 0.02 | < 0.02 | 52.23 |
| 4 | 998.7 | 180.39 | 34.456 | 32.93 | 4.44 | 2.26 | < 0.02 | < 0.02 | 52.39 |
| 5 | 998.7 | 180.21 | 34.457 | 32.84 | 4.44 | 2.26 | < 0.02 | < 0.02 | 52.35 |
| 6 | 998.7 | 180.30 | 34.458 | 32.88 | 4.44 | 2.26 | < 0.02 | < 0.02 | 52.29 |
| 33 | 998.8 | 180.43 | 34.456 | 32.96 | 4.44 | 2.26 | < 0.02 | < 0.02 | 52.16 |
| 32 | 998.8 | 180.61 | 34.457 | 32.98 | 4.44 | 2.26 | < 0.02 | < 0.02 | 52.20 |
| 31 | 998.8 | 180.30 | 34.456 | 32.87 | 4.44 | 2.26 | < 0.02 | < 0.02 | 52.24 |
| 35 | 998.8 | 180.07 | 34.456 | 32.84 | 4.43 | 2.25 | < 0.02 | < 0.02 | 52.20 |
| 28 | 998.8 | 180.43 | 34.456 | 32.89 | 4.43 | 2.25 | < 0.02 | < 0.02 | 52.10 |
| 11 | 998.8 | 180.21 | 34.454 | 32.87 | 4.44 | 2.26 | < 0.02 | < 0.02 | 52.20 |
| 29 | 998.8 | 180.25 | 34.456 | 32.90 | 4.43 | 2.26 | < 0.02 | < 0.02 | 52.19 |
| 27 | 998.8 | 180.74 | 34.456 | 32.89 | 4.43 | 2.26 | < 0.02 | < 0.02 | 52.15 |
| 13 | 998.8 | 180.48 | 34.456 | 32.85 | 4.44 | 2.26 | < 0.02 | < 0.02 | 52.17 |
| 18 | 998.8 | 180.39 | 34.455 | 32.97 | 4.44 | 2.26 | < 0.02 | < 0.02 | 52.10 |
| 9 | 998.8 | 180.61 | 34.456 | 32.88 | 4.44 | 2.26 | < 0.02 | < 0.02 | 52.29 |
| 20 | 998.8 | 180.97 | 34.455 | 32.99 | 4.44 | 2.26 | < 0.02 | < 0.02 | 52.06 |
| 8 | 998.8 | 180.16 | 34.456 | 32.84 | 4.44 | 2.26 | < 0.02 | < 0.02 | 52.29 |
| 21 | 998.8 | 181.81 | 34.457 | 32.90 | 4.44 | 2.27 | < 0.02 | < 0.02 | 52.04 |
| 17 | 998.8 | 180.43 | 34.455 | 32.94 | 4.44 | 2.26 | < 0.02 | < 0.02 | 52.13 |
| 19 | 998.8 | 183.78 | 34.455 | 32.93 | 4.44 | 2.26 | < 0.02 | < 0.02 | 52.07 |
| 16 | 998.8 | 180.61 | 34.455 | 32.99 | 4.44 | 2.26 | < 0.02 | < 0.02 | 52.17 |
| 23 | 998.8 | 180.34 | 34.456 | 33.02 | 4.44 | 2.26 | < 0.02 | < 0.02 | 52.19 |
| 22 | 998.8 | 181.77 | 34.456 | 32.91 | 4.44 | 2.25 | < 0.02 | < 0.02 | 52.12 |
| 15 | 998.8 | 180.61 | 34.456 | 32.94 | 4.44 | 2.26 | < 0.02 | < 0.02 | 52.18 |
| 24 | 998.8 | 180.52 | 34.455 | 32.92 | 4.43 | 2.26 | < 0.02 | < 0.02 | 52.22 |
| 14 | 998.8 | 180.52 | 34.455 | 33.02 | 4.44 | 2.26 | < 0.02 | < 0.02 | 52.16 |
| 7 | 998.8 | 180.48 | 34.456 | 32.84 | 4.44 | 2.26 | < 0.02 | < 0.02 | 52.31 |
| 30 | 998.8 | 180.39 | 34.456 | 32.96 | 4.43 | 2.26 | < 0.02 | < 0.02 | 52.14 |
| 34 | 998.9 | 180.34 | 34.456 | 32.94 | 4.44 | 2.26 | < 0.02 | < 0.02 | 52.16 |
| 36 | 998.9 | 180.30 | 34.456 | 32.99 | 4.42 | 2.25 | < 0.02 | < 0.02 | 52.23 |
| 26 | 998.9 | 180.39 | 34.456 | 32.87 | 4.43 | 2.26 | < 0.02 | < 0.02 | 52.20 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
| Chlorophyll - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 25 - SN 4774 | Seabird | SBE4C | 4774 | |
| Licor - CTD 25 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 25-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Turbidity (%) |
| Temperature CTD 25-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 25 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |