Please login if you have access to particular applications.
Deployment Details
Survey: - IN2023_V02 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 14
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24-SN 2235,Licor - CTD 24 - SN 70562,Oxygen CTD 24 - SN 4187,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Seabird SBE SUNA - SN NTR1890,Temperature CTD 24-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2023-04-11 02:22 to 2023-04-11 02:46 UTC
Where: 43° 42.0' S 146° 00.0' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 20 | 7.2 | < 0.02 | < 0.02 | < 0.02 | 15.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 7.6 | < 0.02 | < 0.02 | < 0.02 | 15.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 7.6 | < 0.02 | < 0.02 | < 0.02 | 15.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 7.9 | < 0.02 | < 0.02 | < 0.02 | 15.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 8 | < 0.02 | < 0.02 | < 0.02 | 15.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 8.1 | < 0.02 | < 0.02 | < 0.02 | 15.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 8.1 | < 0.02 | < 0.02 | < 0.02 | 15.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 8.3 | 247.51 | 35.322 | 1.59 | 15.10 | 0.24 | 0.12 | 0.45 | 0.58 |
| 32 | 8.3 | < 0.02 | < 0.02 | < 0.02 | 15.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 8.4 | < 0.02 | < 0.02 | < 0.02 | 15.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 8.4 | < 0.02 | < 0.02 | < 0.02 | 15.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 8.4 | < 0.02 | < 0.02 | < 0.02 | 15.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 8.4 | < 0.02 | < 0.02 | < 0.02 | 15.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 8.5 | < 0.02 | < 0.02 | < 0.02 | 15.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 8.8 | < 0.02 | < 0.02 | < 0.02 | 15.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 8.8 | < 0.02 | < 0.02 | < 0.02 | 15.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 8.9 | < 0.02 | < 0.02 | < 0.02 | 15.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 9.1 | < 0.02 | < 0.02 | < 0.02 | 15.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 9.2 | < 0.02 | < 0.02 | < 0.02 | 15.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 9.4 | < 0.02 | < 0.02 | < 0.02 | 15.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 19.8 | < 0.02 | < 0.02 | < 0.02 | 15.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 20.3 | 247.47 | 35.322 | 1.59 | 15.06 | 0.24 | 0.10 | 0.46 | 0.57 |
| 13 | 40.1 | < 0.02 | < 0.02 | < 0.02 | 15.04 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 40.4 | 247.96 | 35.326 | 1.33 | 15.04 | 0.22 | 0.12 | 0.45 | 0.57 |
| 11 | 60.1 | < 0.02 | < 0.02 | < 0.02 | 15.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 60.4 | 247.82 | 35.328 | 1.29 | 15.03 | 0.22 | 0.14 | 0.45 | 0.58 |
| 9 | 80.4 | 233.67 | 35.267 | 4.81 | 14.16 | 0.45 | < 0.02 | 0.14 | 1.25 |
| 10 | 80.7 | < 0.02 | < 0.02 | < 0.02 | 14.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 100.5 | < 0.02 | < 0.02 | < 0.02 | 13.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 100.7 | 259.21 | 35.228 | 7.02 | 13.53 | 0.59 | < 0.02 | 0.09 | 1.77 |
| 6 | 120.3 | < 0.02 | < 0.02 | < 0.02 | 12.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 120.6 | 225.05 | 35.172 | 9.12 | 12.76 | 0.75 | < 0.02 | 0.16 | 2.27 |
| 3 | 140.8 | 226.25 | 35.149 | 9.80 | 12.52 | 0.79 | < 0.02 | 0.18 | 2.49 |
| 4 | 140.9 | < 0.02 | < 0.02 | < 0.02 | 12.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 156.7 | < 0.02 | < 0.02 | < 0.02 | 11.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 157.2 | 231.43 | 35.077 | 10.81 | 11.92 | 0.84 | < 0.02 | 0.12 | 2.89 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Conductivity CTD 24-SN 2235 | Seabird | SBE-4C | 2235 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24 - SN 4187 | Seabird | SBE43 | 4187 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
| Seabird SBE SUNA - SN NTR1890 | Seabird | SBE SUNA | NTR1890 | Nitrate (µM) |
| Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |