Deployment Details
Survey: - IN2018_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 8
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 2312,Licor - CTD 24 - SN 70677,Oxygen CTD 24 - SN 3534,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1735DR
When: 2018-12-03 19:17 to 2018-12-03 19:58 UTC
Where: 44° 12.9' S 146° 11.5' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2023 | 6.1 | 261.36 | 35.302 | 2.86 | 13.67 | 0.32 | 0.06 | 0.22 | 1.03 |
2022 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 13.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2035 | 6.4 | < 0.02 | < 0.02 | < 0.02 | 13.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2024 | 6.6 | < 0.02 | < 0.02 | < 0.02 | 13.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2034 | 6.7 | < 0.02 | < 0.02 | < 0.02 | 13.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2036 | 6.7 | < 0.02 | < 0.02 | < 0.02 | 13.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2021 | 6.8 | < 0.02 | < 0.02 | < 0.02 | 13.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2030 | 6.9 | < 0.02 | < 0.02 | < 0.02 | 13.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2029 | 7 | < 0.02 | < 0.02 | < 0.02 | 13.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2020 | 7.2 | < 0.02 | < 0.02 | < 0.02 | 13.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2031 | 7.2 | < 0.02 | < 0.02 | < 0.02 | 13.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2033 | 7.3 | < 0.02 | < 0.02 | < 0.02 | 13.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2025 | 7.3 | < 0.02 | < 0.02 | < 0.02 | 13.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2019 | 7.3 | 261.27 | 35.301 | 2.85 | 13.67 | 0.32 | 0.05 | 0.22 | 1.05 |
2028 | 7.4 | < 0.02 | < 0.02 | < 0.02 | 13.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2123 | 7.6 | < 0.02 | < 0.02 | < 0.02 | 13.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2026 | 7.8 | < 0.02 | < 0.02 | < 0.02 | 13.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2027 | 7.8 | < 0.02 | < 0.02 | < 0.02 | 13.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2017 | 20.7 | 261.00 | 35.302 | 2.86 | 13.68 | 0.32 | 0.05 | 0.22 | 1.04 |
2018 | 20.8 | < 0.02 | < 0.02 | < 0.02 | 13.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2015 | 49 | 260.69 | 35.303 | 2.99 | 13.67 | 0.32 | 0.03 | 0.22 | 1.09 |
2016 | 49.2 | < 0.02 | < 0.02 | < 0.02 | 13.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1214 | 80.5 | < 0.02 | < 0.02 | < 0.02 | 13.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2013 | 80.5 | 252.83 | 35.281 | 6.10 | 13.08 | 0.51 | < 0.02 | 0.20 | 1.70 |
2012 | 99.6 | < 0.02 | < 0.02 | < 0.02 | 13.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2011 | 99.8 | 249.88 | 35.305 | 6.77 | 13.08 | 0.56 | < 0.02 | 0.04 | 2.04 |
2009 | 201.2 | 251.66 | 35.179 | 8.54 | 12.20 | 0.67 | < 0.02 | 0.02 | 2.26 |
2010 | 201.4 | < 0.02 | < 0.02 | < 0.02 | 12.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1201 | 299.4 | < 0.02 | < 0.02 | < 0.02 | 11.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2008 | 299.6 | 252.51 | 35.052 | 10.67 | 11.37 | 0.81 | < 0.02 | < 0.02 | 2.98 |
2006 | 400.9 | < 0.02 | < 0.02 | < 0.02 | 10.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2005 | 400.9 | 240.32 | 34.795 | 15.36 | 10.01 | 1.09 | < 0.02 | < 0.02 | 4.63 |
12004 | 500.7 | < 0.02 | < 0.02 | < 0.02 | 9.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12003 | 500.9 | 227.77 | 34.708 | 18.37 | 9.22 | 1.29 | < 0.02 | < 0.02 | 7.14 |
12001 | 624.6 | 213.88 | 34.544 | 23.00 | 7.89 | 1.58 | < 0.02 | < 0.02 | 11.94 |
12002 | 624.9 | < 0.02 | < 0.02 | < 0.02 | 7.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 2312 | Seabird | SBE4C | 2312 | |
Licor - CTD 24 - SN 70677 | QCP | 2300 | 70677 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |