Deployment Details
Survey: - IN2018_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 3
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 2312,Licor - CTD 24 - SN 70677,Oxygen CTD 24 - SN 3534,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1735DR
When: 2018-11-28 04:03 to 2018-11-28 05:00 UTC
Where: 44° 15.6' S 147° 05.8' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2034 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 13.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2027 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 13.73 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2033 | 6.2 | < 0.02 | < 0.02 | < 0.02 | 13.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2023 | 6.2 | < 0.02 | < 0.02 | < 0.02 | 13.73 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2028 | 6.2 | < 0.02 | < 0.02 | < 0.02 | 13.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2024 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 13.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2026 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 13.73 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2022 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 13.73 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2031 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 13.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2019 | 6.3 | < 0.02 | 35.185 | 1.11 | 13.73 | 0.22 | 0.03 | 0.09 | 0.74 |
2035 | 6.4 | < 0.02 | < 0.02 | < 0.02 | 13.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2036 | 6.4 | < 0.02 | < 0.02 | < 0.02 | 13.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2029 | 6.5 | < 0.02 | < 0.02 | < 0.02 | 13.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2025 | 6.5 | < 0.02 | < 0.02 | < 0.02 | 13.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2030 | 6.5 | < 0.02 | < 0.02 | < 0.02 | 13.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2020 | 6.5 | 281.99 | < 0.02 | < 0.02 | 13.73 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2021 | 6.6 | < 0.02 | < 0.02 | < 0.02 | 13.73 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2123 | 6.6 | < 0.02 | < 0.02 | < 0.02 | 13.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2017 | 50.5 | < 0.02 | 35.210 | 3.39 | 13.17 | 0.40 | 0.73 | 0.25 | 1.00 |
2018 | 50.6 | 265.78 | < 0.02 | < 0.02 | 13.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2016 | 80.7 | 256.85 | < 0.02 | < 0.02 | 12.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2015 | 80.8 | < 0.02 | 35.215 | 6.57 | 12.67 | 0.56 | 0.07 | 0.47 | 1.75 |
2013 | 100.6 | < 0.02 | 35.203 | 8.04 | 12.44 | 0.65 | < 0.02 | 0.20 | 2.31 |
1214 | 100.6 | 251.17 | < 0.02 | < 0.02 | 12.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2011 | 202 | < 0.02 | 35.136 | 9.20 | 11.96 | 0.72 | < 0.02 | 0.08 | 2.72 |
2012 | 202 | 252.20 | < 0.02 | < 0.02 | 11.96 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2010 | 300.2 | 222.32 | < 0.02 | < 0.02 | 10.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2009 | 300.2 | < 0.02 | 34.892 | 15.37 | 10.63 | 1.09 | < 0.02 | < 0.02 | 5.47 |
1201 | 400.4 | < 0.02 | 34.764 | 17.13 | 9.72 | 1.20 | < 0.02 | < 0.02 | 6.04 |
2008 | 400.5 | 230.76 | < 0.02 | < 0.02 | 9.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2005 | 500.5 | < 0.02 | 34.698 | 19.46 | 9.05 | 1.36 | < 0.02 | < 0.02 | 8.60 |
2006 | 500.7 | 221.65 | < 0.02 | < 0.02 | 9.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12003 | 601.6 | < 0.02 | 34.579 | 23.30 | 8.01 | 1.61 | < 0.02 | < 0.02 | 13.52 |
12004 | 601.8 | 207.72 | < 0.02 | < 0.02 | 8.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12001 | 714.6 | < 0.02 | 34.477 | 26.79 | 6.70 | 1.84 | < 0.02 | < 0.02 | 20.55 |
12002 | 714.7 | 200.62 | < 0.02 | < 0.02 | 6.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 2312 | Seabird | SBE4C | 2312 | |
Licor - CTD 24 - SN 70677 | QCP | 2300 | 70677 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |