Voyage: IN2015_C02       [details]
Subject: EM122 will not start pinging, failed BIST tests, troubleshooting
When: 2015-12-10 23:57:00 UTC

- entered into Elog/Everlog as 2015-12-10 23:57:00
Log: GSM_in2015_c02
Equipment: EM122

Kongsberg EM122 12kHz multibeam echo sounder [view]
Position: Latitude: -35.179 Longitude: 130.69967

- entered into Elog as 35°10.74'S, 130°41.98'E
Action: Crash
Comments:

BIST tests failed. Restarted both PC and computer. BISTS passesd but still will not ping. Ran extended telnet BIST. Failed Preamplifier tests (51 and 53). TUrned off SBP, EM122 PC and transducer and then turned off preamplified. Turned back on and booted EM122 back up. Re-ran preamplifier BISTS. Still failed. Start pinging- shows pings being fired in Ksync but does not show pings in SIS. Telnet shows "No attitude" messages. Possibly a problem with the pre-amplifier unit so the pings are being sent but not properly recieved.