Deployment Details
Survey: - IN2016_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 5
Gear: Autosal Salinometer,CTD 20 - SN 0552,CTD 22,Conductivity CTD 20 - SN 3309,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Oxygen CTD 20-SBE 43-SN 3159,Pressure CTD 20,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 20 - SN 5450,Temperature CTD 22-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2016-11-03 10:02 to 2016-11-03 12:13 UTC
Where: 27° 12.9' S 154° 40.3' E
Maximum Depth (m): 4841.5
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
1215 | 6.5 | 215.13 | 35.604 | 0.02 | 24.31 | 0.10 | < 0.02 | 0.53 |
1214 | 20.2 | 215.89 | 35.602 | 0.02 | 24.32 | 0.10 | < 0.02 | 0.54 |
1213 | 49.6 | 216.74 | 35.658 | 0.02 | 23.63 | 0.12 | < 0.02 | 0.57 |
1224 | 80.5 | 201.78 | 35.676 | 0.77 | 23.30 | 0.20 | 0.07 | 0.72 |
1223 | 100.5 | 196.91 | 35.712 | 1.70 | 22.58 | 0.24 | 0.14 | 0.74 |
1222 | 149.8 | 209.33 | 35.760 | 1.51 | 21.33 | 0.22 | 0.21 | 0.69 |
1221 | 199.9 | 214.60 | 35.774 | 1.59 | 20.57 | 0.21 | 0.02 | 0.65 |
1220 | 280.5 | 208.52 | 35.726 | 2.82 | 19.67 | 0.29 | 0.02 | 0.86 |
1219 | 350.5 | 195.97 | 35.578 | 5.72 | 18.05 | 0.48 | 0.02 | 1.64 |
1218 | 450.5 | 190.12 | 35.286 | 10.50 | 14.95 | 0.78 | < 0.02 | 3.33 |
1217 | 549.4 | 198.79 | 35.015 | 14.79 | 12.14 | 1.05 | < 0.02 | 5.27 |
1216 | 649.4 | 201.69 | 34.761 | 19.39 | 9.92 | 1.33 | < 0.02 | 8.04 |
1212 | 750.8 | 203.83 | 34.568 | 23.55 | 8.18 | 1.61 | < 0.02 | 13.14 |
1211 | 849 | 203.07 | 34.478 | 26.30 | 6.97 | 1.80 | < 0.02 | 19.42 |
1210 | 999.9 | 193.78 | 34.442 | 29.68 | 5.60 | 2.04 | < 0.02 | 33.94 |
1209 | 1199.6 | 178.24 | 34.474 | 32.68 | 4.47 | 2.26 | < 0.02 | 56.24 |
1208 | 1499.6 | 158.55 | 34.544 | 35.15 | 3.49 | 2.46 | < 0.02 | 83.80 |
1207 | 1798.9 | 157.21 | 34.630 | 35.57 | 2.61 | 2.49 | < 0.02 | 101.58 |
1206 | 2199.8 | 179.67 | 34.697 | 33.61 | 2.13 | 2.33 | < 0.02 | 96.13 |
1205 | 2599.2 | 189.41 | 34.719 | 33.14 | 1.79 | 2.29 | < 0.02 | 103.42 |
1204 | 3000.4 | 195.75 | 34.723 | 33.17 | 1.47 | 2.29 | < 0.02 | 111.18 |
1203 | 4001.1 | 201.24 | 34.715 | 33.54 | 1.17 | 2.31 | < 0.02 | 120.70 |
1202 | 4500.2 | 201.64 | 34.713 | 33.59 | 1.19 | 2.32 | < 0.02 | 121.65 |
1201 | 4841.5 | 201.69 | 34.714 | 33.59 | 1.22 | 2.32 | < 0.02 | 122.11 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
CTD 22 | Seabird | Seabird SBE911 | 1243 | |
Conductivity CTD 20 - SN 3309 | Seabird | SBE4C | 3309 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 20-SBE 43-SN 3159 | Seabird | SBE 43 | 3159 | Oxygen (µM) |
Pressure CTD 20 | Digiquartz | 410K-134 | 552 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 20 - SN 5450 | Seabird | SBE3 plus | 5450 | Temperature (deg C) |
Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |