Deployment Details
Survey: - SS200704 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 107
Operation No.: 1
Gear: Autosal Salinometer,CTD 20 - SN 0552,Conductivity CTD 20-SN 3169,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Oxygen-CTD 20-Optode SN 716-Foil 4804,Pressure CTD 20-SN 75638,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 20-SN 2751,Transmissometer - CTD 20 -CST-1016DR
When: 2007-06-04 04:45 to 2007-06-04 05:38 UTC
Where:
22° 00.1' S
113° 40.1' E
to
22° 00.0' S
113° 39.7' E
Maximum Depth (m): 976
CTD profile - view full size
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
1066 | 1.6 | 26.47 | ||||||
1068 | 1.7 | 26.47 | ||||||
1070 | 1.7 | 26.47 | ||||||
1065 | 2 | 202.80 | 35.120 | 0.12 | 26.47 | 0.07 | 0.08 | 3.60 |
1069 | 2 | 26.47 | ||||||
1064 | 8.4 | 0.10 | 26.48 | 0.09 | 0.09 | 3.62 | ||
1063 | 23.6 | 0.10 | 26.47 | 0.07 | 0.08 | 3.57 | ||
1058 | 48.5 | 0.13 | 26.46 | 0.07 | 0.09 | 3.52 | ||
1059 | 48.6 | 26.46 | ||||||
1060 | 48.9 | 26.46 | ||||||
1061 | 49.3 | 26.46 | ||||||
1062 | 49.3 | 26.46 | ||||||
1067 | 73.3 | 0.09 | 26.43 | 0.08 | 0.10 | 3.68 | ||
1056 | 98.7 | 0.42 | 26.40 | 0.09 | 0.17 | 4.16 | ||
1055 | 167.7 | 8.15 | 22.20 | 0.60 | 0.07 | 10.60 | ||
1054 | 250 | 2.85 | 18.19 | 0.24 | 0.05 | 3.44 | ||
1053 | 495.3 | 221.30 | 34.615 | 20.16 | 8.56 | 1.33 | 0.03 | 11.06 |
1052 | 974.2 | 5.17 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 62021 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Conductivity CTD 20-SN 3169 | Seabird | SBE-4 | 3169 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen-CTD 20-Optode SN 716-Foil 4804 | Aanderaa | Optode 3975 | 716 | Optode (micromole/litre) |
Pressure CTD 20-SN 75638 | Paroscientific I | 410K-105 | 75638 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 20-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer - CTD 20 -CST-1016DR | WET Labs | C-Star | CST-1016DR | Transmittance (%) |