Deployment Details
Survey: - IN2023_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 10
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Conductivity CTD 24-SN 2235,Licor - CTD 24 - SN 70562,Oxygen CTD 24 - SN 4187,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24-SN 2751
When: 2023-06-15 15:00 to 2023-06-15 18:39 UTC
Where: 47° 28.3' S 144° 54.6' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
31 | 29.6 | 261.27 | < 0.02 | 7.96 | 11.95 | 0.64 | < 0.02 | 0.05 | 1.77 |
35 | 29.9 | < 0.02 | < 0.02 | 7.92 | 11.95 | 0.64 | < 0.02 | 0.04 | 1.76 |
32 | 30.3 | < 0.02 | 35.108 | 7.95 | 11.95 | 0.64 | < 0.02 | 0.05 | 1.73 |
36 | 30.3 | < 0.02 | < 0.02 | 7.93 | 11.95 | 0.64 | < 0.02 | 0.05 | 1.77 |
34 | 31 | < 0.02 | < 0.02 | 7.96 | 11.95 | 0.64 | < 0.02 | 0.04 | 1.69 |
33 | 31.2 | < 0.02 | < 0.02 | 7.95 | 11.95 | 0.64 | < 0.02 | 0.05 | 1.72 |
30 | 100.3 | < 0.02 | < 0.02 | 8.43 | 11.75 | 0.67 | < 0.02 | 0.05 | 1.79 |
28 | 100.3 | 262.52 | < 0.02 | 8.43 | 11.69 | 0.67 | < 0.02 | 0.05 | 1.77 |
29 | 100.4 | < 0.02 | 35.060 | 8.44 | 11.70 | 0.67 | < 0.02 | 0.05 | 1.75 |
27 | 400.7 | < 0.02 | < 0.02 | 14.91 | 9.52 | 1.06 | < 0.02 | 0.02 | 3.52 |
26 | 400.8 | < 0.02 | 34.663 | 14.91 | 9.52 | 1.07 | 0.02 | 0.02 | 3.55 |
25 | 401 | 260.64 | < 0.02 | 14.91 | 9.52 | 1.07 | < 0.02 | 0.02 | 3.53 |
23 | 700 | < 0.02 | 34.557 | 21.93 | 8.31 | 1.50 | < 0.02 | 0.02 | 9.59 |
22 | 700.4 | 220.40 | < 0.02 | 21.96 | 8.31 | 1.50 | < 0.02 | < 0.02 | 9.57 |
24 | 700.9 | < 0.02 | < 0.02 | 21.92 | 8.31 | 1.50 | < 0.02 | 0.02 | 9.48 |
19 | 1000.6 | 202.31 | < 0.02 | 28.90 | 5.82 | 1.98 | < 0.02 | < 0.02 | 26.68 |
21 | 1000.7 | < 0.02 | < 0.02 | 28.90 | 5.82 | 1.98 | < 0.02 | < 0.02 | 26.72 |
20 | 1000.9 | < 0.02 | 34.411 | 28.91 | 5.82 | 1.98 | < 0.02 | < 0.02 | 26.72 |
18 | 1300.7 | < 0.02 | < 0.02 | 33.16 | 4.10 | 2.28 | < 0.02 | < 0.02 | 56.62 |
17 | 1400.6 | < 0.02 | < 0.02 | 34.05 | 3.68 | 2.37 | < 0.02 | < 0.02 | 66.14 |
16 | 1500.7 | < 0.02 | < 0.02 | 34.67 | 3.26 | 2.42 | < 0.02 | < 0.02 | 72.24 |
14 | 1600.5 | 168.77 | < 0.02 | 34.83 | 2.97 | 2.43 | < 0.02 | 0.02 | 77.53 |
15 | 1600.7 | < 0.02 | 34.554 | 34.85 | 2.97 | 2.43 | < 0.02 | < 0.02 | 77.51 |
13 | 1700.5 | < 0.02 | < 0.02 | 34.80 | 2.83 | 2.42 | < 0.02 | < 0.02 | 80.86 |
12 | 1850.5 | < 0.02 | < 0.02 | 34.28 | 2.59 | 2.39 | < 0.02 | < 0.02 | 84.29 |
11 | 2000.6 | < 0.02 | < 0.02 | 33.41 | 2.47 | 2.32 | < 0.02 | < 0.02 | 81.68 |
10 | 2300.7 | < 0.02 | < 0.02 | 32.73 | 2.25 | 2.27 | < 0.02 | < 0.02 | 89.06 |
9 | 2600.4 | < 0.02 | < 0.02 | 32.55 | 2.00 | 2.26 | < 0.02 | < 0.02 | 98.91 |
7 | 2700.6 | 189.72 | < 0.02 | 32.47 | 1.93 | 2.25 | < 0.02 | < 0.02 | 100.85 |
8 | 2700.6 | < 0.02 | 34.735 | 32.46 | 1.93 | 2.26 | < 0.02 | < 0.02 | 100.88 |
6 | 2799.9 | < 0.02 | < 0.02 | 32.43 | 1.86 | 2.25 | < 0.02 | < 0.02 | 102.84 |
5 | 3201 | < 0.02 | < 0.02 | 32.37 | 1.54 | 2.25 | < 0.02 | < 0.02 | 110.19 |
4 | 3900.7 | < 0.02 | < 0.02 | 32.84 | 1.18 | 2.28 | < 0.02 | < 0.02 | 120.96 |
3 | 4350.7 | < 0.02 | < 0.02 | 33.02 | 1.06 | 2.30 | < 0.02 | < 0.02 | 123.90 |
1 | 4448.5 | 207.85 | < 0.02 | < 0.02 | 1.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 4448.7 | < 0.02 | 34.712 | 33.07 | 1.07 | 2.29 | < 0.02 | < 0.02 | 123.75 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Conductivity CTD 24-SN 2235 | Seabird | SBE-4C | 2235 | |
Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 4187 | Seabird | SBE43 | 4187 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |