Deployment Details
Survey: - IN2023_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 9
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Conductivity CTD 24-SN 2235,Licor - CTD 24 - SN 70562,Oxygen CTD 24 - SN 4187,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24-SN 2751
When: 2023-06-14 17:04 to 2023-06-14 20:40 UTC
Where: 49° 53.3' S 143° 48.0' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
36 | 30.1 | < 0.02 | 34.582 | 13.26 | 9.22 | 0.99 | < 0.02 | 0.12 | 2.41 |
35 | 30.3 | 278.91 | < 0.02 | 13.30 | 9.22 | 0.99 | < 0.02 | 0.12 | 2.51 |
34 | 51.1 | < 0.02 | < 0.02 | 13.34 | 9.22 | 0.99 | < 0.02 | 0.13 | 2.55 |
33 | 80.8 | < 0.02 | < 0.02 | 13.35 | 9.23 | 0.99 | < 0.02 | 0.12 | 2.55 |
32 | 101.7 | < 0.02 | < 0.02 | 13.38 | 9.23 | 1.00 | < 0.02 | 0.12 | 2.50 |
31 | 151.7 | < 0.02 | 34.593 | 13.39 | 9.27 | 0.99 | < 0.02 | 0.13 | 2.43 |
30 | 151.8 | 277.93 | < 0.02 | 13.40 | 9.27 | 0.99 | < 0.02 | 0.13 | 2.38 |
29 | 203.8 | < 0.02 | < 0.02 | 13.40 | 9.27 | 0.99 | < 0.02 | 0.13 | 2.39 |
28 | 300.7 | < 0.02 | < 0.02 | 13.41 | 9.29 | 0.99 | < 0.02 | 0.12 | 2.41 |
27 | 404.7 | < 0.02 | < 0.02 | 14.42 | 9.35 | 1.05 | < 0.02 | 0.02 | 3.22 |
26 | 501 | < 0.02 | < 0.02 | 15.56 | 9.16 | 1.11 | < 0.02 | < 0.02 | 3.76 |
25 | 602.2 | < 0.02 | < 0.02 | 18.07 | 8.96 | 1.26 | < 0.02 | < 0.02 | 5.41 |
24 | 699.8 | < 0.02 | 34.540 | 21.02 | 8.30 | 1.45 | < 0.02 | < 0.02 | 8.28 |
23 | 699.9 | 230.27 | < 0.02 | 21.06 | 8.30 | 1.45 | < 0.02 | < 0.02 | 8.31 |
22 | 797.9 | < 0.02 | < 0.02 | 24.46 | 7.44 | 1.67 | < 0.02 | < 0.02 | 13.02 |
21 | 901.4 | < 0.02 | < 0.02 | 27.66 | 6.25 | 1.88 | < 0.02 | 0.02 | 19.91 |
19 | 1001.4 | 213.52 | < 0.02 | 29.71 | 5.20 | 2.03 | < 0.02 | 0.02 | 25.76 |
20 | 1001.7 | < 0.02 | 34.340 | 29.71 | 5.19 | 2.03 | < 0.02 | 0.02 | 25.75 |
18 | 1101.9 | < 0.02 | < 0.02 | 31.46 | 4.34 | 2.16 | < 0.02 | < 0.02 | 33.85 |
17 | 1250 | < 0.02 | < 0.02 | 32.95 | 3.71 | 2.28 | < 0.02 | < 0.02 | 43.03 |
16 | 1350 | < 0.02 | < 0.02 | 33.87 | 3.39 | 2.35 | < 0.02 | < 0.02 | 51.61 |
15 | 1500.7 | < 0.02 | < 0.02 | 34.62 | 3.08 | 2.41 | < 0.02 | < 0.02 | 61.88 |
14 | 1600.6 | < 0.02 | < 0.02 | 34.60 | 2.84 | 2.41 | < 0.02 | < 0.02 | 66.78 |
12 | 1698.9 | 178.69 | < 0.02 | 34.50 | 2.74 | 2.39 | < 0.02 | < 0.02 | 70.13 |
13 | 1699 | < 0.02 | 34.549 | 34.41 | 2.74 | 2.39 | < 0.02 | < 0.02 | 69.90 |
11 | 1799.8 | < 0.02 | < 0.02 | 33.95 | 2.64 | 2.36 | < 0.02 | < 0.02 | 73.00 |
10 | 1997.5 | < 0.02 | < 0.02 | 33.08 | 2.53 | 2.30 | < 0.02 | < 0.02 | 76.14 |
9 | 2199.6 | < 0.02 | < 0.02 | 32.13 | 2.36 | 2.22 | < 0.02 | < 0.02 | 79.49 |
8 | 2499.1 | < 0.02 | < 0.02 | 31.05 | 2.10 | 2.15 | < 0.02 | < 0.02 | 85.78 |
7 | 2599.9 | < 0.02 | 34.744 | 30.87 | 2.03 | 2.15 | < 0.02 | < 0.02 | 88.09 |
6 | 2600 | 199.14 | < 0.02 | 30.95 | 2.03 | 2.15 | < 0.02 | < 0.02 | 88.36 |
5 | 2701.4 | < 0.02 | < 0.02 | 31.08 | 1.85 | 2.16 | < 0.02 | < 0.02 | 93.22 |
4 | 2999.9 | < 0.02 | < 0.02 | 31.64 | 1.51 | 2.21 | < 0.02 | 0.02 | 105.45 |
3 | 3399.5 | < 0.02 | < 0.02 | 32.10 | 1.19 | 2.25 | < 0.02 | < 0.02 | 116.22 |
2 | 3701.3 | < 0.02 | 34.714 | 32.37 | 1.07 | 2.26 | < 0.02 | < 0.02 | 120.07 |
1 | 3701.3 | 211.07 | < 0.02 | < 0.02 | 1.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Conductivity CTD 24-SN 2235 | Seabird | SBE-4C | 2235 | |
Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 4187 | Seabird | SBE43 | 4187 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |