Deployment Details
Survey: - IN2023_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 3
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Conductivity CTD 24-SN 2235,Licor - CTD 24 - SN 70562,Oxygen CTD 24 - SN 4187,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24-SN 2751
When: 2023-06-07 17:02 to 2023-06-07 21:06 UTC
Where: 46° 48.1' S 142° 21.4' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 25.5 | 282.61 | < 0.02 | 14.42 | 9.15 | 1.06 | < 0.02 | 0.17 | 2.66 |
36 | 25.9 | < 0.02 | 34.508 | 14.38 | 9.15 | 1.06 | < 0.02 | 0.17 | 2.68 |
34 | 50.5 | < 0.02 | < 0.02 | 14.40 | 9.15 | 1.06 | < 0.02 | 0.17 | 2.66 |
33 | 81.6 | < 0.02 | < 0.02 | 14.39 | 9.16 | 1.06 | < 0.02 | 0.17 | 2.67 |
32 | 90.3 | < 0.02 | < 0.02 | 14.48 | 9.10 | 1.06 | < 0.02 | 0.17 | 2.69 |
31 | 101 | < 0.02 | 34.517 | 14.50 | 9.09 | 1.07 | < 0.02 | 0.17 | 2.69 |
30 | 101.5 | 281.19 | < 0.02 | 14.49 | 9.09 | 1.06 | < 0.02 | 0.17 | 2.68 |
29 | 200.4 | < 0.02 | < 0.02 | 14.25 | 9.18 | 1.05 | < 0.02 | 0.14 | 2.70 |
28 | 300.7 | < 0.02 | < 0.02 | 14.10 | 9.59 | 1.03 | < 0.02 | 0.05 | 3.28 |
27 | 399.1 | < 0.02 | < 0.02 | 15.19 | 9.50 | 1.10 | < 0.02 | 0.02 | 4.03 |
26 | 499.5 | < 0.02 | < 0.02 | 17.26 | 9.06 | 1.23 | < 0.02 | < 0.02 | 5.00 |
25 | 600.3 | < 0.02 | < 0.02 | 19.39 | 8.51 | 1.36 | < 0.02 | < 0.02 | 6.83 |
23 | 699.1 | 227.99 | < 0.02 | 22.56 | 7.80 | 1.56 | < 0.02 | < 0.02 | 10.37 |
24 | 699.7 | < 0.02 | 34.485 | 22.54 | 7.80 | 1.56 | < 0.02 | < 0.02 | 10.37 |
22 | 800.5 | < 0.02 | < 0.02 | 25.31 | 7.02 | 1.73 | < 0.02 | < 0.02 | 14.48 |
21 | 900.6 | < 0.02 | < 0.02 | 28.00 | 5.91 | 1.92 | < 0.02 | < 0.02 | 19.88 |
19 | 999.6 | 215.22 | < 0.02 | 29.93 | 5.00 | 2.06 | < 0.02 | < 0.02 | 26.57 |
20 | 1000.2 | < 0.02 | 34.327 | 29.97 | 4.99 | 2.05 | < 0.02 | < 0.02 | 26.57 |
18 | 1199.6 | < 0.02 | < 0.02 | 32.85 | 3.69 | 2.27 | < 0.02 | < 0.02 | 41.15 |
17 | 1499.8 | < 0.02 | < 0.02 | 34.55 | 3.26 | 2.42 | < 0.02 | < 0.02 | 70.87 |
16 | 1600.8 | < 0.02 | 34.552 | 34.77 | 2.99 | 2.44 | < 0.02 | < 0.02 | 77.12 |
15 | 1601.1 | 168.60 | < 0.02 | 34.69 | 2.99 | 2.44 | < 0.02 | < 0.02 | 77.22 |
14 | 1699.8 | < 0.02 | < 0.02 | 34.50 | 2.74 | 2.41 | < 0.02 | < 0.02 | 78.18 |
13 | 1801.2 | < 0.02 | < 0.02 | 33.99 | 2.62 | 2.38 | < 0.02 | < 0.02 | 77.55 |
12 | 2000.8 | < 0.02 | < 0.02 | 33.20 | 2.46 | 2.33 | < 0.02 | < 0.02 | 81.84 |
11 | 2351.1 | < 0.02 | < 0.02 | 32.61 | 2.22 | 2.30 | < 0.02 | < 0.02 | 92.50 |
10 | 2700.1 | < 0.02 | < 0.02 | 32.44 | 1.97 | 2.29 | < 0.02 | < 0.02 | 100.82 |
9 | 2800.6 | < 0.02 | 34.733 | 32.43 | 1.89 | 2.28 | < 0.02 | < 0.02 | 103.50 |
8 | 2801.1 | 189.45 | < 0.02 | 32.42 | 1.89 | 2.29 | < 0.02 | < 0.02 | 103.48 |
7 | 2901.1 | < 0.02 | < 0.02 | 32.38 | 1.81 | 2.28 | < 0.02 | < 0.02 | 105.23 |
6 | 3000.7 | < 0.02 | < 0.02 | 32.38 | 1.75 | 2.28 | < 0.02 | < 0.02 | 106.82 |
5 | 3498.9 | < 0.02 | < 0.02 | 32.34 | 1.46 | 2.27 | < 0.02 | < 0.02 | 113.43 |
4 | 3798.4 | < 0.02 | < 0.02 | 32.45 | 1.31 | 2.28 | < 0.02 | < 0.02 | 116.73 |
3 | 4200.5 | < 0.02 | < 0.02 | 32.81 | 1.05 | 2.30 | < 0.02 | < 0.02 | 122.59 |
1 | 4611.4 | 209.19 | < 0.02 | < 0.02 | 1.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 4612.2 | < 0.02 | 34.710 | 32.87 | 1.06 | 2.31 | < 0.02 | < 0.02 | 123.82 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Conductivity CTD 24-SN 2235 | Seabird | SBE-4C | 2235 | |
Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 4187 | Seabird | SBE43 | 4187 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |