Please login if you have access to particular applications.
Deployment Details
Survey: - IN2023_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 1
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Conductivity CTD 24-SN 2235,Licor - CTD 24 - SN 70562,Oxygen CTD 24 - SN 4187,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24-SN 2751
When: 2023-06-05 19:13 to 2023-06-05 21:03 UTC
Where: 44° 43.2' S 146° 02.4' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 31 | 1649 | < 0.02 | < 0.02 | 35.01 | 2.88 | 2.43 | < 0.02 | < 0.02 | 76.83 |
| 33 | 1649.1 | < 0.02 | < 0.02 | 35.03 | 2.88 | 2.44 | < 0.02 | < 0.02 | 76.92 |
| 27 | 1649.1 | < 0.02 | < 0.02 | < 0.02 | 2.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 1649.3 | < 0.02 | < 0.02 | 34.99 | 2.88 | 2.43 | < 0.02 | < 0.02 | 76.92 |
| 26 | 1649.3 | < 0.02 | < 0.02 | < 0.02 | 2.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 1649.4 | < 0.02 | < 0.02 | 35.02 | 2.88 | 2.43 | < 0.02 | < 0.02 | 76.88 |
| 28 | 1649.4 | < 0.02 | < 0.02 | 34.99 | 2.88 | 2.43 | < 0.02 | < 0.02 | 76.87 |
| 22 | 1649.4 | < 0.02 | 34.562 | 35.00 | 2.88 | 2.43 | < 0.02 | < 0.02 | 76.98 |
| 19 | 1649.4 | 173.69 | < 0.02 | < 0.02 | 2.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 1649.5 | 173.82 | < 0.02 | 35.00 | 2.88 | 2.43 | < 0.02 | < 0.02 | 76.86 |
| 23 | 1649.5 | < 0.02 | 34.562 | 35.00 | 2.88 | 2.43 | < 0.02 | < 0.02 | 76.81 |
| 24 | 1649.6 | < 0.02 | 34.562 | 34.95 | 2.88 | 2.44 | < 0.02 | < 0.02 | 76.97 |
| 29 | 1649.6 | < 0.02 | < 0.02 | 34.95 | 2.88 | 2.43 | < 0.02 | < 0.02 | 76.89 |
| 20 | 1649.7 | 173.73 | < 0.02 | 35.01 | 2.88 | 2.43 | < 0.02 | < 0.02 | 77.05 |
| 34 | 1649.7 | < 0.02 | < 0.02 | 34.96 | 2.88 | 2.43 | < 0.02 | < 0.02 | 76.99 |
| 25 | 1649.7 | < 0.02 | < 0.02 | < 0.02 | 2.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 1649.8 | < 0.02 | < 0.02 | 34.96 | 2.88 | 2.43 | < 0.02 | < 0.02 | 77.01 |
| 35 | 1650.1 | < 0.02 | < 0.02 | 34.96 | 2.88 | 2.44 | 0.15 | < 0.02 | 76.96 |
| 15 | 2700 | < 0.02 | < 0.02 | 33.08 | 1.88 | 2.30 | < 0.02 | < 0.02 | 105.23 |
| 1 | 2700.1 | 190.26 | < 0.02 | < 0.02 | 1.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 2700.1 | < 0.02 | 34.732 | 33.07 | 1.88 | 2.30 | < 0.02 | < 0.02 | 105.29 |
| 2 | 2700.1 | 189.05 | < 0.02 | 33.08 | 1.88 | 2.30 | < 0.02 | < 0.02 | 104.87 |
| 9 | 2700.1 | < 0.02 | < 0.02 | < 0.02 | 1.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 2700.2 | < 0.02 | 34.739 | 33.11 | 1.88 | 2.30 | < 0.02 | < 0.02 | 105.28 |
| 16 | 2700.2 | < 0.02 | < 0.02 | 33.11 | 1.88 | 2.30 | < 0.02 | < 0.02 | 105.26 |
| 12 | 2700.2 | < 0.02 | < 0.02 | 33.06 | 1.88 | 2.30 | < 0.02 | < 0.02 | 105.17 |
| 3 | 2700.2 | 189.36 | < 0.02 | 33.07 | 1.88 | 2.29 | < 0.02 | < 0.02 | 105.11 |
| 10 | 2700.2 | < 0.02 | < 0.02 | 33.07 | 1.88 | 2.30 | < 0.02 | < 0.02 | 104.95 |
| 11 | 2700.3 | < 0.02 | < 0.02 | 33.07 | 1.88 | 2.30 | < 0.02 | < 0.02 | 105.20 |
| 14 | 2700.3 | < 0.02 | < 0.02 | 33.14 | 1.88 | 2.30 | < 0.02 | < 0.02 | 105.15 |
| 18 | 2700.3 | < 0.02 | < 0.02 | 33.09 | 1.88 | 2.30 | < 0.02 | < 0.02 | 104.76 |
| 4 | 2700.3 | < 0.02 | 34.732 | 33.06 | 1.88 | 2.30 | < 0.02 | < 0.02 | 105.19 |
| 17 | 2700.4 | < 0.02 | < 0.02 | 33.09 | 1.88 | 2.30 | < 0.02 | < 0.02 | 105.14 |
| 7 | 2700.5 | 189.72 | < 0.02 | < 0.02 | 1.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 2700.5 | < 0.02 | < 0.02 | < 0.02 | 1.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 2700.6 | < 0.02 | < 0.02 | 33.06 | 1.88 | 2.30 | < 0.02 | < 0.02 | 105.13 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Conductivity CTD 24-SN 2235 | Seabird | SBE-4C | 2235 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24 - SN 4187 | Seabird | SBE43 | 4187 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
| Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |