Deployment Details
Survey: - IN2023_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 30
Gear: Autosal Salinometer,CTD 24 - SN 1332,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24-SN 2751
When: 2023-10-15 10:38 to 2023-10-15 12:48 UTC
Where: 35° 34.9' S 154° 20.0' E
Maximum Depth (m): 2000.4
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 17.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 17.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 17.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 6.5 | < 0.02 | < 0.02 | < 0.02 | 17.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 6.6 | 247.56 | 35.595 | 0.20 | 17.47 | 0.13 | 0.03 | 0.05 | 0.48 |
30 | 19.6 | < 0.02 | < 0.02 | 0.21 | 17.47 | 0.13 | 0.04 | 0.05 | 0.46 |
31 | 20.3 | < 0.02 | < 0.02 | < 0.02 | 17.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 40.2 | < 0.02 | < 0.02 | < 0.02 | 17.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 40.4 | 246.22 | 35.602 | 0.34 | 17.44 | 0.13 | 0.11 | 0.06 | 0.45 |
26 | 60.2 | < 0.02 | < 0.02 | 0.48 | 17.37 | 0.13 | 0.20 | 0.08 | 0.49 |
27 | 60.6 | < 0.02 | < 0.02 | < 0.02 | 17.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 80.3 | < 0.02 | < 0.02 | < 0.02 | 16.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 80.4 | < 0.02 | < 0.02 | < 0.02 | 16.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 80.5 | 232.64 | 35.520 | 3.68 | 16.24 | 0.34 | < 0.02 | 0.37 | 1.31 |
21 | 100.6 | 229.16 | 35.482 | 4.98 | 15.61 | 0.41 | < 0.02 | 0.08 | 1.72 |
22 | 100.7 | < 0.02 | < 0.02 | < 0.02 | 15.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 124.8 | < 0.02 | < 0.02 | 5.73 | 15.32 | 0.46 | < 0.02 | 0.04 | 1.87 |
19 | 150.2 | < 0.02 | < 0.02 | 8.03 | 14.84 | 0.61 | < 0.02 | 0.03 | 2.50 |
18 | 180.4 | < 0.02 | < 0.02 | 9.10 | 14.29 | 0.68 | < 0.02 | 0.02 | 2.86 |
17 | 200.4 | < 0.02 | < 0.02 | 8.77 | 13.98 | 0.67 | < 0.02 | 0.02 | 2.74 |
16 | 221.2 | 221.52 | 35.287 | 8.88 | 13.77 | 0.68 | < 0.02 | 0.03 | 2.75 |
15 | 300.6 | 208.70 | 35.056 | 13.55 | 12.08 | 0.96 | < 0.02 | 0.02 | 4.46 |
14 | 350.3 | < 0.02 | < 0.02 | 15.46 | 11.22 | 1.08 | < 0.02 | 0.03 | 5.23 |
13 | 400.1 | 210.13 | 34.838 | 17.21 | 10.54 | 1.19 | < 0.02 | 0.03 | 6.06 |
12 | 501 | 214.55 | 34.687 | 19.81 | 9.37 | 1.36 | < 0.02 | 0.02 | 7.38 |
11 | 600.9 | < 0.02 | < 0.02 | 22.85 | 8.35 | 1.56 | < 0.02 | 0.02 | 11.16 |
10 | 700.9 | < 0.02 | < 0.02 | 25.45 | 7.39 | 1.73 | < 0.02 | 0.02 | 16.12 |
8 | 800.7 | < 0.02 | < 0.02 | 27.80 | 6.45 | 1.89 | < 0.02 | 0.02 | 23.11 |
9 | 800.7 | 199.05 | 34.454 | 27.77 | 6.45 | 1.90 | < 0.02 | 0.02 | 23.05 |
7 | 1000.5 | 185.75 | 34.446 | 31.34 | 5.06 | 2.14 | < 0.02 | 0.02 | 42.11 |
6 | 1099.5 | < 0.02 | < 0.02 | 32.52 | 4.58 | 2.23 | < 0.02 | < 0.02 | 51.83 |
5 | 1200.6 | 173.60 | 34.480 | 33.58 | 4.10 | 2.32 | < 0.02 | < 0.02 | 60.43 |
4 | 1400.1 | < 0.02 | < 0.02 | 35.13 | 3.37 | 2.44 | < 0.02 | < 0.02 | 81.28 |
3 | 1600.3 | 158.01 | 34.599 | 35.57 | 2.84 | 2.47 | < 0.02 | < 0.02 | 91.88 |
2 | 1800.1 | < 0.02 | < 0.02 | 35.11 | 2.55 | 2.44 | < 0.02 | < 0.02 | 94.08 |
1 | 2000.4 | 170.96 | 34.668 | 34.38 | 2.33 | 2.39 | < 0.02 | < 0.02 | 94.01 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |