Argo profile pressure correction

This page is automatically created by code which scans all files in the Argo USGODAE GDAC.

Plots and listings analysing the pressure correction for floats of each DAC are accessed through the Plots Index Tables.


Summary stats of DAC vs Audit pressure correction differences

Pressure Correction (all floats)
AOMLBODCCORIOLISCSIRONMDISJMAMEDSCSIOINCOISKMAKORDITotal all DACs
# floats39773631262474110733171092371471198079
Any DM275929789433408092186314611405634
DM - missing P ADJ1059000122018092
RT - missing P ADJ14959540113596612661802
New format tech397236212624731106431699236147918023
SP offset deduced397236212624731106431699236147918023
P=Praw-SP2691321696468090428095227130875899
P type unknown254181046034371461732522
Pcor varies in prof00000512000017
Some Praw-Padj28893391068464094830263222130556480
Some valid SP37733451161468110353089523113007547
Some DAC vs Audit test2887339106546409453025722213006411
Results of DAC vs Audit Pcor comparisons - Auto-correcting floats
All agree82224398007000001251
All diffs < 1dbar20000430000045
Some diffs > 1dbar10000210000022
80% > 1dbar000000000000
Results of DAC vs Audit Pcor comparisons - Correction-required floats
Prof data but no SP10300300005562
All agree16782482833790757128341344003681
All diffs < 1dbar34964297750837818675401085
Some diffs > 1dbar293181002772521360221
80% > 1dbar203001462915078
Median Min Adjusted Profile Pressure
Med MPP < 2.5dbar3952174032101500313
Med MPP < 7.5dbar267627175844008462354820447505575
Med MPP < 12.51376511406864152545416
Med MPP > 12.5265736501101280155

Pressure Correction [apex floats only]
AOMLBODCCORIOLISCSIRONMDISJMAMEDSCSIOINCOISKMAKORDITotal all DACs
# floats1955335596461084828289211138935008
Any DM118827341332207121885714011403407
DM - missing P ADJ0048000122018080
RT - missing P ADJ1118954007596612661418
New format tech1953334596461084028289210138914994
SP offset deduced1953334596461084028289210138914994
P=Praw-SP1892319584456083828087207130874880
P type unknown511612501022486116
Pcor varies in prof00000512000017
Some Praw-Padj1530315590453083827857207130554453
Some valid SP190531958745608352808720713004806
Some DAC vs Audit test152931558745308352785720713004391
Results of DAC vs Audit Pcor comparisons - Auto-correcting floats
All agree000000000000
All diffs < 1dbar000000000000
Some diffs > 1dbar000000000000
80% > 1dbar000000000000
Results of DAC vs Audit Pcor comparisons - Correction-required floats
Prof data but no SP00300300005561
All agree11562482673690748128341334003123
All diffs < 1dbar34464297740757818645401068
Some diffs > 1dbar293171001172510360193
80% > 1dbar202000462015067
Median Min Adjusted Profile Pressure
Med MPP < 2.5dbar611240010150039
Med MPP < 7.5dbar146325251343508332344818947504064
Med MPP < 12.55354712034192545231
Med MPP > 12.575715101101280111

Table updated on 05-Dec-2011, GDAC state as at 25 Nov 2011


Explanation of categories


All values are the number of floats exhibiting the described conditions for each DAC.

# floats number of floats in total
Any DM number of floats with any DM files
DM - missing P ADJ floats with some DM files having empty or missing PRES_ADJUSTED (where there is a non-empty PRES profile)
RT - missing P ADJ floats with some RT files having empty or missing PRES_ADJUSTED (where there is a non-empty PRES profile)
New format tech tech file has new format

The following pressure correction aspects are deduced for each float based on the Surface Pressure Offset parameter name.
These deductions are recorded in this table.


SP offset deduced the Apex SP adjustment (ie 5 dbar, or 0 dbar) can be resolved (or guessed) from the surface pressure parameter name
P=Praw-SP pressure does required correction by subtracting SP
P type unknown don't know if is the above type of float
Pcor varies in prof Praw-Padj is not constant through profile. This now excludes SOLOs where deepest ADJUSTED pressure is correct forincomplete bin averaging.
Some Praw-Padj float does have some Praw and corresponding Padj values, so a "DAC correction" can be resolved.
Some valid SP tech file has some plausible SP values (only required where pressure has to be corrected with SP)
Some DAC vs Audit test some pressure correction comparisons can be made for these floats
All agree all DAC corrections agree exactly with our estimates
All diffs < 1dbar some discrepancy, but these are all < 1dbar
Some diffs > 1dbar some discrepancies are large (> 1 dbar)
80% > 1dbar 80% of DAC corrections disagree with our estimatesby at least 1dbar
The minimum (ie near-surface) profile pressure value will normally be about 5 dbar for the Apex floats. We examine the median of these values for each float series, as another coarse guide to correct calibration.
Med MPP < 2.5dbar (such cases often have MPP near zero - maybe self-calibrating pressure?)
Med MPP < 7.5dbar 2.5< MPP<7.5 - mostly close to 5 dbar
Med MPP < 12.5 7.5< MPP<12.5 - many of these are ~ 10dbar ??
Med MPP > 12.5 presumably some bad pressures

 

Legal Notice and Disclaimer | Copyright | Privacy | Page author: Jeff Dunn | Contact: Jeff.Dunn@csiro.au