TNPD detection and treatment

This page is automatically created by code which scans all files in the Argo USGODAE GDAC.

Plots and listings analysing the Surface Pressure for TNPD floats for each DAC are accessed through the Plots Index Tables.


TNPD detected, and Reponses in D files

TNPD
AOMLBODCCORIOLISCSIROGTSJMAMEDSCSIOINCOISKMAKORDITotal all DACs
# floats391134812604663501072317952331521148318
Trunc & known offset1052245407225-67321544139104-3104
Floats apparently truncating and known offset, but corrected SP is negative at some stage
(ignoring whether profiles are DM or RT)
Very few -ve SP331-3-113622-61
more -ve SPs1----2-----3
min SP > -13--1-15-11-12
min SP = -5151-1-112---21
min SP < -51-----3----4
Floats with apparent TNPD
TNPD whole series169535327-10524153417-497
TNPD part series255545434-14938142715-640
Counts of floats with these conditions in TNPD D-file profiles
TNPD in D-files2871047445-21041275131-870
TNPD 6months DM269956142-18136234827-782
Some QC=1187224329-18627163122-563
Some min(QC)=2225904943-7225264610-586
Some min(QC)=3416---13-----33
Some min(QC)=48242710-536-122-214
Imperfect COMMENTS present------17--17-34
Some COMMENTS present230944945-6992647--569
Some COMMENTS absent9124306-1542141116-357
Some min err 2.4314836945-20744165131-860
Some min err 2025121718-115267--121
Some not 2.4 or 20-20---------20

Table based on GDAC as at 01-Nov-2011


Explanation of categories

All values are the number of floats exhibiting the described conditions for each DAC.

# floats - number of floats in each DAC

Trunc & known offset - floats which are believed (from info in tech and meta files) to be a type which truncates, and for which the fixed firmware surface offset value (eg 5dbar) is known.

Floats apparently truncating and known offset, but corrected SP is negative at some stage - In theory this should not happen, however the occasional small -ve value is not a worry. Frequent or large negatives could arise from the float being wrongly identified as a truncating type. Values of exactly -5 can indicate missing SP reported as 0, or maybe 5dbar offset removed twice!

TNPD whole series - truncating floats with no +ve SP

TNPD part series - truncating floats with no +ve SP after some point

All the following conditions are determined for the D-files only.

TNPD in D-files - floats with TNPD in DM processed profiles (rather than only in profiles which have not yet been DM processed.)

TNPD 6months DM - floats with TNPD in DM processed profiles spanning at least 18 cycles, so would expect TNPD status to be acknowledged.

Some QC=1 - floats with some TNPD profiles with minimum PRES_ADJUSTED_QC==1

Some QC=2 - floats with some TNPD profiles with minimum PRES_ADJUSTED_QC==2

Some QC=3 - floats with some TNPD profiles with minimum PRES_ADJUSTED_QC==3

Some QC=4 - floats with some TNPD profiles with minimum PRES_ADJUSTED_QC==4

Looking for the approved TNPD comment string in the SCIENTIFIC_CALIB_COMMENTS variable. Now allow for the first dimension of that variable, NCALIB to be >1 (thanks to John Gilson). However, I still expect to find the TNPD string in the parts of the variable that correspond to the pressure parameter. That is, we always expect PARAMETER(1,:) = 'PRES', so any comments associated with pressure should be in SCIENTIFIC_CALIB_COMMENTS(n,1,:)

Imperfect COMMENTS present - floats where some profiles have comment containing "ncated" and "TNPD" or "TNDP", but not the full correct string.

Some COMMENTS present - floats where some profiles have correct TNPD comment.

Some COMMENTS absent - - floats where some of TNPD profiles do NOT have a correct or even imperfect TNPD comment.

Some min err 2.4 - floats where some of TNPD profiles have a minimum PRES_ADJUSTED_ERROR of 2.4

Some min err 20 - floats where some of TNPD profiles have a minimum PRES_ADJUSTED_ERROR of 20

Some not 2.4 or 20 - floats where some of TNPD profiles have a minimum PRES_ADJUSTED_ERROR of neither 2.4 nor 20.

 

Legal Notice and Disclaimer | Copyright | Privacy | Page author: Jeff Dunn | Contact: Jeff.Dunn@csiro.au