TNPD detection and treatment

This page is automatically created by code which scans all files in the Argo USGODAE GDAC.

Plots and listings analysing the Surface Pressure for TNPD floats for each DAC are accessed through the Plots Index Tables.


TNPD detected, and Reponses in D files

TNPD
AOMLBODCCORIOLISCSIROGTSJMAMEDSCSIOINCOISKMAKORDITotal all DACs
# floats35433241182361373958300671951421197564
Trunc & known offset1051244404218-67221342139104-3087
Floats apparently truncating and known offset, but corrected SP is negative at some stage
Very few -ve SP301-1-113512-54
more -ve SPs2----12----5
min SP > -13--1-15-11-12
min SP = -5151---112---20
min SP < -5------5----5
Floats with apparent TNPD
TNPD whole series173545527-10825143417-507
TNPD part series254545233-14334132315-621
Counts of floats with these conditions in TNPD D-file profiles
TNPD in D-files284986549-20539205128-839
TNPD 6months DM267925345-18135164724-760
Some QC=1151222231-21130202713-527
Some min(QC)=2189874543-317-4416-444
Some min(QC)=3916---2-----27
Some min(QC)=4814159-485-112-202
Imperfect COMMENTS present15----17--16-39
Some COMMENTS present188914545-1--45--415
Some COMMENTS absent14418247-20424201113-465
Some min err 2.4284806647-20341204728-816
Some min err 20912318-14-7--54
Some not 2.4 or 203020---------50

Table based on GDAC as at 18-Dec-2010


Explanation of categories

All values are the number of floats exhibiting the described conditions for each DAC. The first 4 categories do not distinguish between RT and DM profiles.

# floats - number of floats in each DAC

Trunc & known offset - floats which are believed (from info in tech and meta files) to be a type which truncates, and for which the fixed firmware surface offset value (eg 5dbar) is known.

TNPD whole series - truncating floats with no +ve SP

TNPD part series - truncating floats with no +ve SP after some point

All the following conditions are determined for the D-files only.

TNPD in D-files - floats with TNPD in DM processed profiles (rather than only in profiles which have not yet been DM processed.)

TNPD 6months DM - floats with TNPD in DM processed profiles spanning at least 18 cycles, so would expect TNPD status to be acknowledged.

Some QC=1 - floats with some TNPD profiles with minimum PRES_ADJUSTED_QC==1

Some QC=2 - floats with some TNPD profiles with minimum PRES_ADJUSTED_QC==2

Some QC=3 - floats with some TNPD profiles with minimum PRES_ADJUSTED_QC==3

Some QC=4 - floats with some TNPD profiles with minimum PRES_ADJUSTED_QC==4

Looking for the approved TNPD comment string in the SCIENTIFIC_CALIB_COMMENTS variable. Now allow for the first dimension of that variable, NCALIB to be >1 (thanks to John Gilson). However, I still expect to find the TNPD string in the parts of the variable that correspond to the pressure parameter. That is, we always expect PARAMETER(1,:) = 'PRES', so any comments associated with pressure should be in SCIENTIFIC_CALIB_COMMENTS(n,1,:)

Imperfect COMMENTS present - floats where some profiles have comment containing "ncated" and "TNPD" or "TNDP", but not the full correct string.

Some COMMENTS present - floats where some profiles have correct TNPD comment.

Some COMMENTS absent - - floats where some of TNPD profiles do NOT have a correct or even imperfect TNPD comment.

Some min err 2.4 - floats where some of TNPD profiles have a minimum PRES_ADJUSTED_ERROR of 2.4

Some min err 20 - floats where some of TNPD profiles have a minimum PRES_ADJUSTED_ERROR of 20

Some not 2.4 or 20 - floats where some of TNPD profiles have a minimum PRES_ADJUSTED_ERROR of neither 2.4 nor 20.

 

Legal Notice and Disclaimer | Copyright | Privacy | Page author: Jeff Dunn | Contact: Jeff.Dunn@csiro.au