Pressure correction choices based on SPO parameter name

This analysis was based on GDAC at 18-Dec-2010

The following table records operator decisions [guesses] affecting the pressure correction treatment for each float, based on the tech file surface pressure offset parameter name.

NOTE:Pressure treatment is presently based strictly on surface pressure offset parameter name. Many SOLO and maybe some PROVOR/Martec floats auto-correct despite using names like"pres_surfaceoffsetnottruncated_dbar", so these will appearto be wrongly corrected.

Parameter NameNo correctionCorrection Type 1TruncatingSP Adjust (dbar)
Old format tech files - ignored
New format tech files
Missing X . no -
pres_surfaceoffsettruncatedplus5dbar_dbar. X yes 5
pres_surfaceoffsettruncated_dbar. X yes 0
pres_surfaceoffsetnottruncatedplus5dbar_dbar. X no 5
pres_surfaceoffsetnottruncated_dbar. X no 0
pres_surfaceoffsetbeforereset_dbar. X no 0
pres_surfaceoffsetbeforereset_1dbarresolution_dbar. X no 0
pres_surfaceoffsetbeforereset_1cbarresolution_dbar. X no 0
pres_surfaceoffsetafterreset_dbar X . no 0
pres_offsetadjustment_dbar. X no 0
pressure_offset_dbar X . no 0
pres_surfacecomplement_dbar X . no 0
pres_surface_dbar X . no 0
pres_surfaceoffsettruncatedplus3dbar_dbar. X yes 3
pres_surfaceoffsetnottrancated_dbar. X no 0

Glossary

No correction: either the pressure does not need adjustment for SP, or we do not know what adjustment to do.

Correction Type 1:

       RT profiles: P-SP(n)  
       DM profiles: P-SP(n+1)  

Truncating: a type which truncated SP

SP Adjust (dbar): eg 5 (dbar) for many Apex floats