TNDP detection and treatment
This page is automatically created by code which scans all files
in the Argo USGODAE GDAC.
Plots and listings analysing the Surface Pressure for TNDP floats
for each DAC are accessed through the
Plots Index Tables.
TNDP detected, and Reponses in D files
TNDP [Apex floats only]
| AOML | BODC | CORIOLIS | CSIRO | GTS | JMA | MEDS | CSIO | INCOIS | KMA | KORDI | Total all DACs |
# floats | 1678 | 286 | 474 | 323 | 1 | 795 | 263 | 52 | 168 | 133 | 79 | 4252 |
Trunc & known offset | 1034 | 244 | 401 | 208 | - | 673 | 217 | 42 | 139 | 104 | - | 3062 |
Floats apparently truncating and known offset, but corrected SP is negative at some stage |
Very few -ve SP | 27 | 1 | - | 1 | - | 11 | 12 | 5 | 1 | 2 | - | 60 |
more -ve SPs | 1 | - | - | - | - | 652 | 2 | - | - | - | - | 655 |
min SP > -1 | 3 | - | - | 1 | - | 1 | 5 | - | 1 | 1 | - | 12 |
min SP = -5 | 13 | 1 | - | - | - | 546 | 1 | 2 | - | - | - | 563 |
min SP < -5 | - | - | - | - | - | 5 | 5 | - | - | - | - | 10 |
Floats with apparent TNDP |
TNDP whole series | 169 | 54 | 52 | 27 | - | 8 | 26 | 14 | 34 | 17 | - | 401 |
TNDP part series | 290 | 68 | 67 | 47 | - | 1 | 40 | 16 | 30 | 16 | - | 575 |
Counts of floats with these conditions in TNDP D-file profiles |
TNDP in D-files | 294 | 111 | 70 | 54 | - | 3 | 41 | 23 | 52 | 12 | - | 660 |
Some QC=1 | 293 | 28 | 72 | 45 | - | 2 | 40 | 22 | 36 | 13 | - | 551 |
Some min(QC)=2 | 61 | 96 | - | 44 | - | - | 13 | - | 42 | - | - | 256 |
Some min(QC)=3 | 10 | 17 | - | - | - | - | - | - | - | - | - | 27 |
Some min(QC)=4 | 82 | 42 | 5 | 12 | - | 2 | 5 | - | 11 | - | - | 159 |
Some COMMENTS present | 49 | 22 | 42 | 44 | - | - | - | - | 43 | - | - | 200 |
Some COMMENTS absent | 266 | 95 | 30 | 11 | - | 3 | 41 | 23 | 13 | 12 | - | 494 |
Some min err 2.4 | 253 | 52 | 22 | 31 | - | 2 | 37 | 22 | 44 | 11 | - | 474 |
Some min err 20 | - | 13 | - | 18 | - | - | 3 | - | 7 | - | - | 41 |
Some not 2.4 or 20 | 32 | 43 | - | - | - | - | - | - | - | - | - | 75 |
Note: apparently extremely few TNDP detected for JMA. This is because JMA
Surface Pressure is usually not raw, but has already been adjusted by -5 dbar
(so the majority of SP ~= -5.) We could allow for this in the analysis if desired.
Table updated on 10-Oct-2010
Explanation of categories
All values are the number of floats exhibiting the described conditions
for each DAC. The first 4 categories do not distinguish between RT and DM
profiles.
# floats - number of floats in each DAC
Trunc & known offset - floats which are believed
(from info in tech and meta files) to be a type which truncates, and for which
the fixed firmware surface offset value (eg 5dbar) is known.
TNDP whole series - truncating floats with no +ve SP
TNDP part series - truncating floats with no +ve SP after some
point
All the following conditions are determined for the D-files only.
TNDP in D-files - floats with TNDP in DM processed profiles (rather
than only in profiles which have not yet been DM processed.)
Some QC=1 - floats with some TNDP profiles with minimum PRES_ADJUSTED_QC==1
Some QC=2 - floats with some TNDP profiles with minimum PRES_ADJUSTED_QC==2
Some QC=3 - floats with some TNDP profiles with minimum PRES_ADJUSTED_QC==3
Some QC=4 - floats with some TNDP profiles with minimum PRES_ADJUSTED_QC==4
Some TNDP COMMENTS present - floats where some of TNDP profiles have correct
pressure SCIENTIFIC_CALIB_COMMENTS for TNDP
Some TNDP COMMENTS absent - - floats where some of TNDP profiles do NOT have
correct pressure SCIENTIFIC_CALIB_COMMENTS for TNDP
Some min err 2.4 - floats where some of TNDP profiles have a
minimum PRES_ADJUSTED_ERROR of 2.4
Some min err 20 - floats where some of TNDP profiles have a
minimum PRES_ADJUSTED_ERROR of 20
Some not 2.4 or 20 - floats where some of TNDP profiles have a
minimum PRES_ADJUSTED_ERROR of neither 2.4 nor 20.
|